CHAPTER 2 SETUP PROCEDURE
2.2 Removal of Acrylic Board
To modify the clock setting, the acrylic board on the bottom of the QB-78K0FX2 must be removed.
The acrylic board can be removed by lifting it up.
Figure 2-2. Acrylic Board Removal Method
2.3 Clock Settings
2.3.1 Overview of clock settings
The following 5 types of clock settings are available.
For details, see 2.3.2 Clock setting methods.
Main system clock
(1) Use the internally generated clock
(2) Use a target system clock
(3) Generate the clock from the oscillator mounted on OSC1.
Subsystem clock
(1) Use the internally generated clock
(2) Use a target system clock
User’s Manual U17669EJ3V0UM
21