English
Language : 

HYS72T32000HP Datasheet, PDF (20/53 Pages) Qimonda AG – 240-Pin Registered DDR2 SDRAM Modules
Internet Data Sheet
HYS72T[32/64]xxxHP–[3S/3.7]–A
Registered DDR2 SDRAM Modules
Parameter
Symbol
DDR2–667
Min.
Max.
Unit
Note1)2)3)4)5)6)7)
8)
Four Activate Window for 1KB page size products tFAW
Four Activate Window for 2KB page size products tFAW
CAS to CAS command delay
tCCD
Write recovery time
tWR
Auto-Precharge write recovery + precharge time tDAL
Internal write to read command delay
tWTR
Internal Read to Precharge command delay
tRTP
Exit self-refresh to a non-read command
tXSNR
Exit self-refresh to read command
tXSRD
Exit precharge power-down to any valid
tXP
command (other than NOP or Deselect)
37.5
—
50
—
2
—
15
—
WR + tnRP
—
7.5
—
7.5
—
tRFC +10
—
200
—
2
—
ns
ns
nCK
ns
nCK
ns
ns
ns
nCK
nCK
1)
1)
1)
29)30)
1)31)
1)
1)
Exit power down to read command
Exit active power-down mode to read command
(slow exit, lower power)
CKE minimum pulse width ( high and low pulse
width)
tXARD
tXARDS
tCKE
2
—
7 – AL
—
3
—
nCK
nCK
nCK
32)
ODT turn-on delay
ODT turn-on
tAOND
tAON
2
tAC.MIN
2
nCK
tAC.MAX + 0.7 ns
1)33)
ODT turn-on (Power down mode)
tAONPD
tAC.MIN + 2
2 x tCK.AVG + ns
tAC.MAX + 1
ODT turn-off delay
ODT turn-off
tAOFD
tAOF
2.5
tAC.MIN
2.5
tAC.MAX + 0.6
nCK
ns
34)35)
ODT turn-off (Power down mode)
tAOFPD
tAC.MIN + 2
2.5 x tCK.AVG + ns
tAC.MAX + 1
ODT to power down entry latency
tANPD
3
––
nCK
ODT to power down exit latency
tAXPD
8
nCK
Mode register set command cycle time
tMRD
2
MRS command to ODT update delay
tMOD
0
—
nCK
12
ns
1)
OCD drive mode output delay
tOIT
0
12
ns
1)
Minimum time clocks remain ON after CKE
tDELAY
tLS + tCK .AVG + ––
ns
asynchronously drops LOW
tLH
1) For details and notes see the relevant QIMONDA component data sheet
2) VDDQ = 1.8 V ± 0.1V; VDD = 1.8 V ± 0.1 V. See notes 1)1)1)1)
3) Timing that is not specified is illegal and after such an event, in order to guarantee proper operation, the DRAM must be powered down
and then restarted through the specified initialization sequence before normal operation can continue.
4) Timings are guaranteed with CK/CK differential Slew Rate of 2.0 V/ns. For DQS signals timings are guaranteed with a differential Slew
Rate of 2.0 V/ns in differential strobe mode and a Slew Rate of 1 V/ns in single ended mode.
5) The CK / CK input reference level (for timing reference to CK / CK) is the point at which CK and CK cross. The DQS / DQS, RDQS / RDQS,
input reference level is the crosspoint when in differential strobe mode.
6) Inputs are not recognized as valid until VREF stabilizes. During the period before VREF stabilizes, CKE = 0.2 x VDDQ is recognized as low.
7) The output timing reference voltage level is VTT.
Rev. 1.01, 2006-09
20