English
Language : 

PSIIX20-12 Datasheet, PDF (1/3 Pages) Powersem GmbH – IGBT Module
ECO-PACTM 2
IGBT Module
PSIIX 20/12
Preliminary Data Sheet
IC25
= 28 A
VCES = 1200 V
V = CE(sat)typ. 2.1 V
IGBTs
O9
P9
L9
A5
C5
A1
C1
G10
H10
S18
E5
G14
E1
W18
I14
K14
K10
PSIIX 20/12
Symbol
VCES
VGES
IC25
IC80
ICM
VCEK
tSC
(SCSOA)
Ptot
Symbol
V
CE(sat)
VGE(th)
ICES
IGES
td(on)
t
r
td(off)
tf
Eon
Eoff
Q
Gon
RthJC
RthJH
Conditions
TVJ = 25°C to 150°C
Maximum Ratings
1200
V Features
± 20
V•
Easy paralleling due to the
TC = 25°C
28
TC = 80°C
17
VGE = ±15 V; RG = 56 Ω; TVJ = 125°C
45
RBSOA, Clamped inductive load; L = 100 µH
VCES
VCE = 900 V; VGE = ±15 V; RG = 56 Ω; TVJ = 125°C
10
non-repetitive
TC = 25°C
100
A
A
A•
µs
W
•
positive temperature coefficient of
the on-state voltage
Rugged XPT design (Xtreme light
Punch Through) results in:
- short circuit rated for 10 µsec.
- very low gate charge
- square RBSOA @ 3x IC
- low EMI
Thin wafer technology combined
with the XPT design results in a
Conditions
Characteristic Values
(TVJ = 25°C, unless otherwise specified) •
min. typ. max.
competitive low VCE(sat)
Industry Standard Package
- solderable pins for PCB
IC = 16 A; VGE = 15 V; TVJ = 25°C
TVJ = 125°C
IC = 0.4 mA; VGE = VCE
VCE = VCES;
VGE = 0 V; TVJ = 25°C
TVJ = 125°C
1.8
2.1
5.5
0.01
0.1
2.1 V
V
6.5 V •
0.1 mA
mounting
- isolated DCB ceramic base
plate
UL release applied
mA Applications
VCE = 0 V; VGE = ± 20 V
500 nA • AC drives
70
n s • power supplies with power factor
40
ns
correction
Inductive load, TVJ = 125°C
VCE = 600 V; IC = 15 A
VGE = ±15 V; RG = 56 Ω
250
ns
100
ns Advantages
1.55
mJ • Easy to mount with two screws
1.7
mJ • Space and weight savings
• Improved temperature and power
VCE = 600 V; VGE = 15 V; IC = 15 A
(per IGBT)
(per IGBT) with heatsink compound
47
nC
1.3 K/W •
tbd
K/W •
cycling capability
High power density
Small and light weight
Caution: These devices are sensitive
to electrostatic discharge. Users should
observe proper ESD handling precautions.
POWERSEM GmbH, Walpersdorfer Str. 53 © 2009 POWERSEM reserves the right to change limits, test conditions and dimensions
D - 91126 Schwabach
Phone: 09122 - 9764 - 0 email: info@powersem.de FAX: 09122 - 9764 - 20