English
Language : 

ZY7015 Datasheet, PDF (25/34 Pages) Power-One – 3V to 13.2V Input 0.5V to 5.5V Output
ZY7015 15A DC-DC Intelligent POL Data Sheet
3V to 13.2V Input • 0.5V to 5.5V Output
The POL powering the output V1 (Ch3 in the picture)
executes the regular turn-off. Since both V1 and V3
have the same delay and slew rate settings they will
continue to turn off and on synchronously every
130ms as shown in Figure 46 until the condition
causing the undervoltage is removed. The POL
powering the output V2 continues to ramp up until it
reaches its steady state level.
130ms is the interval from the instant of time when
the output voltage ramps down to zero until the
output voltage starts to ramp up again. Therefore,
the 130ms hiccup interval is guaranteed regardless
of the turn-off delay setting.
Figure 46. Turn-On into UVP on V3. The UV Fault Is
Programmed To Be Non-Latching and Propagate
From Group C to Group A. Ch1 – V3 (Group C),
Ch2 – V2, Ch3 – V1 (Group A)
Summary of protections, their parameters and
features are shown in Table 3
Figure 45. Turn-On into UVP on V3. The UV Fault Is
Programmed To Be Non-Latching. Ch1 – V3
(Group C), Ch2 – V2, Ch3 – V1 (Group A)
Code
PT
PG
TR
OT
OC
UV
OV
Name
Temperature
Warning
Power Good
Table 3. Summary of Protections Parameters and Features
Type
When Active
Turn
Off
Low Side
Switch
Warning Whenever VIN is applied
No
N/A
Warning
During steady state
No
N/A
Tracking
Fault
During ramp up
Fast
Off
Overtemperature Fault
Whenever VIN is applied Regular
Off
Overcurrent
Fault When VOUT exceeds prebias Fast
Off
Undervoltage
Fault
During steady state
Regular
Off
Overvoltage
Error When VOUT exceeds prebias Fast
On
Propagation
Sends signal to
DPM
Sends signal to
DPM
Regular turn off
Regular turn off
Regular turn off
Regular turn off
Fast turn off
Disable
No
No
Yes
No
No
No
No
ZD-00283 REV. 2.2
www.power-one.com
Page 25 of 34