S/UNI-ATM LAYER SOLUTION
Register 0x214: Ingress Performance Monitoring RAM Data Word 1
Bit
Type
Function
Default
15
R/W
PMData[31]
0
14
R/W
PMData[30]
0
13
R/W
PMData[29]
0
12
R/W
PMData[28]
0
11
R/W
PMData[27]
0
10
R/W
PMData[26]
0
9
R/W
PMData[25]
0
8
R/W
PMData[24]
0
7
R/W
PMData[23]
0
6
R/W
PMData[22]
0
5
R/W
PMData[21]
0
4
R/W
PMData[20]
0
3
R/W
PMData[19]
0
2
R/W
PMData[18]
0
1
R/W
PMData[17]
0
0
R/W
PMData[16]
0
This register contains either the data to be written into the Ingress PM RAM Data Word 1 or the data
read from the internal Ingress PM RAM when a read request has been completed. If data is to be
written to Ingress PM RAM Data Word 1, the word must be written to this register before the Ingress
PM RAM Select and Access Control register are written. If data is to be read from the Ingress PM
RAM this register contains the data from Word 1 after the internal SRAM access is completed.