FRAME ENGINE AND DATA LINK MANAGER
DCHAN[6:0]:
The disable channel number bits (DCHAN[6:0]) selects the channel to be
disabled. When CHDIS is set high, the channel specified by DCHAN[6:0] is
disabled. Data in timeslots associated with the specified channel is set to
FDATA[7:0] in the Idle Time-slot Fill Data register. When CHDIS is set low,
the channel specified by DCHAN[6:0] operates normally.
CHDIS:
The channel disable bit (CHDIS) controls the disabling of the channels
specified by DCHAN[6:0]. When CHDIS is set high, the channel selected by
DCHAN[6:0] is disabled. Data in timeslots associated with the specified
channel is set to FDATA[7:0] in the Idle Time-slot Fill Data register. When
CHDIS is set low, the channel specified by DCHAN[6:0] operates normally.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMER’S INTERNAL USE 232