13.4.3 Diagnostic Digital Loopback
When Diagnostic Digital loopback (DDLB) is initiated by writing 04H to the
Master Diagnostics Register (0AH), the T1XC is configured to internally connect
the dual-rail positive and negative data pulses output from DJAT to the dual-rail
inputs of CDRC. As a result, if DDLB is to be used, TUNI must be set to logic 0
in the Transmit Interface Configuration register (04H) and RUNI must be set to
logic 0 in the Receive Interface Configuration register (03H). Conceptually, the
data flow through T1XC in this loopback condition can be shown as follows: