English
Language : 

PL611S-08 Datasheet, PDF (5/8 Pages) PhaseLink Corporation – Low-Power Programmable Quick Turn ClockTM
DC SPECIFICATIONS
P (Preliminary) L611s-08
Low-Power Programmable Quick Turn ClockTM
PARAMETERS
SYMBOL
CONDITIONS
Supply Current, Dynamic, with
Loaded CMOS Outputs
Supply Current, Dynamic, with
Loaded CMOS Outputs
Supply Current, Dynamic with
Loaded CMOS Outputs
Supply Current, Dynamic, with
Loaded Outputs
Operating Voltage
Output Low Voltage
Output High Voltage
Output Current, Low Drive
Output Current, Standard Drive
Output Current, High Drive
Short-Circuit Current
IDD
@ VDD =3.3V, 27MHz,
load=15pF
IDD
@ VDD =2.5V, 27MHz,
load=15pF
IDD
@ VDD =1.8V,27MHz,
load=5pF
IDD
When PDB=0
VDD
VOL
IOL = +4mA Standard Drive
VOH
IOH = -4mA Standard Drive
IOSD
VOL = 0.4V, VOH = 2.4V
IOSD
VOL = 0.4V, VOH = 2.4V
IOHD
VOL = 0.4V, VOH = 2.4V
IS
* Note: Please contact PhaseLink, if super-low-power is required.
MIN. TYP.
5.5
3.5
1.8*
1.62
VDD – 0.4
4
8
16
±50
MAX. UNITS
mA
mA
mA
<5
µA
3.63
V
0.4
V
V
mA
mA
mA
mA
CRYSTAL SPECIFICATIONS
PARAMETERS
Fundamental Crystal Resonator Frequency
Crystal Loading Rating
(The IC can be programmed for any value in this range.)
Maximum Sustainable Drive Level
Operating Drive Level
Metal Can Crystal
Shunt Capacitance
ESR Max
Small SMD Crystal
Shunt Capacitance
ESR Max
SYMBOL
FXIN
CL (xtal)
C0
ESR
C0
ESR
MIN.
10
8
TYP.
30
MAX.
50
12
100
5.5
50
2.5
80
UNITS
MHz
pF
µW
µW
pF
Ω
pF
Ω
47745 Fremont Blvd., Fremont, California 94538 Tel (510) 492-0990 Fax (510) 492-0991 www.phaselink.com Rev 12/12/06 Page 5