English
Language : 

PL560-XX Datasheet, PDF (5/15 Pages) PhaseLink Corporation – Analog Frequency Multiplier
Analog Frequency Multiplier
PL560-xx VCXO Family
VOLTAGE CONTROL SPECIFICATION
PARAMETERS
VCXO Stabilization Time
VCXO Tuning Range
CLK Output Pullability
Linearity
VCON Input Impedance
VCON Modulation BW
SYMBOL
CONDITIONS
MIN.
TVCXOSTB From power valid
XTAL C0 /C1 <300
200
VCON= 1.65V ± 1.65V
±100
XTAL C0 /C1 <300
130
0V < VCON < 3.3V, -3dB
25
TYP.
±120
5
MAX.
10
10
UNITS
ms
ppm
ppm
%
kΩ
kHz
EXTERNAL COMPONENT VALUES
INDUCTOR VALUE OPTIMIZATION
The required inductor value(s) for the best performance depends on the operating frequency, and the board
layout specifications. The listed values in this datasheet are based on the calculated parasitic values from
PhaseLink’s evaluation board design. These inductor values provide the user with a starting point to determine
the optimum inductor values. Additional fine-tuning may be required to determine the optimal solution.
To assist with the inductor value optimization, PhaseLink has developed the “AFM Tuning Assistant” software.
You can download this software from PhaseLink’s web site (www.phaselink.com). The software consists of two
worksheets. The first worksheet (named L2) is used to fine-tune the ‘L2’ inductor value, and the second
worksheet (named L4) is used for fine tuning of the ‘L4’ (used in 4x AFMs only) inductor value.
For those designs using PhaseLink’s recommended board layout, you can use the “AFM Tuning Assistant” to
determine the optimum values for the required inductors. This software is developed based on the parasitic
information from PhaseLink’s board layout and can be used to determine the required inductor and parallel
capacitor (see LWB1 and Cstray parameters) values. For those employing a different board layout in their
design, we recommend to use the parasitic information of their board layout to calculate the optimized inductor
values. Please use the following fine tuning procedure:
47745 Fremont Blvd., Fremont, CA 94538 TEL (510) 492-0990, FAX (510) 492-0991 www.phaselink.com Rev.:02-09-07 Page 5