English
Language : 

PL611-20 Datasheet, PDF (4/7 Pages) PhaseLink Corporation – Programmable Quick Turn Clock
ELECTRICAL SPECIFICATIONS
PL611-20
Programmable Quick Turn ClockTM
ABSOLUTE MAXIMUM RATINGS
PARAMETERS
SYMBOL
MIN.
MAX.
UNITS
Supply Voltage Range
Input Voltage Range
Output Voltage Range
Data Retention @ 85º C
Soldering Temperature (Green Package)
VDD
-0.5
4.6
V
VI
-0.5
VDD+0.5
V
VO
-0.5
VDD+0.5
V
10
Years
260
°C
Storage Temperature
Ambient Operating Temperature*
TS
-65
150
°C
-40
+85
°C
Exposure of the device under conditions beyond the limits specified by Maximum Ratings for extended periods may cause permanent damage to the device
and affect product reliability. These conditions represent a stress rating only, and functional operations of the device at these or any other conditions above
the operational limits noted in this specification is not implied.
AC SPECIFICATIONS
PARAMETERS
CONDITIONS
MIN. TYP. MAX. UNITS
Crystal Input Frequency
Settling Time
VDD Sensitivity
Output Rise Time
Output Fall Time
Duty Cycle
Fundamental Crystal
10
30
MHz
3rd Overtone Crystal
75
MHz
At power-up (after VDD increases over
1.62V)
10
ms
Frequency vs. VDD+/-10%
-2
2
ppm
15pF Load, 10/90%VDD, Standard drive
2.5
3.5
ns
15pF Load, 10/90%VDD, High drive
1.0
1.5
ns
15pF Load, 90/10%VDD, Standard drive
2.5
3.5
ns
15pF Load, 90/10%VDD, High drive
1.0
1.5
ns
At VDD/2
45
50
55
%
Max. output skew between
same frequency clocks
Equal loading (15 pF). Equal frequency
& drive strength
200
ps
Period Jitter, peak-to-peak*
(measured from 10,000
samples)
With capacitive decoupling between VDD
and GND. Operating only one output.
40
ps
* Note: Jitter performance depends on the programming parameters.
47745 Fremont Blvd., Fremont, California 94538 Tel (510) 492-0990 Fax (510) 492-0991
Rev 07/06/05 Page 4