English
Language : 

BUK212-50Y Datasheet, PDF (6/16 Pages) NXP Semiconductors – Single channel high-side TOPFET™
Philips Semiconductors
BUK212-50Y; BUK217-50Y
Single channel high-side TOPFET™
Table 6: Static characteristics…continued
Limits are valid for −40 °C ≤ Tmb ≤ +150 °C and typical values for Tmb = 25 °C unless otherwise specified.
Symbol Parameter
Conditions
Min Typ
Undervoltage [10]
VBG(uv)
battery-ground undervoltage
[8] 2
4.2
VBG(uv)(hys) battery-ground undervoltage
hysteresis
-
0.5
Overvoltage [10]
VBG(ov)
battery-ground overvoltage
[9] 35
45
VBG(ov)(hys) battery-ground overvoltage
hysteresis
-
1
Overload protection [10]
IL(lim)
self-limiting load current
Short circuit load protection
VBG ≥ 9 V; VBL = VBG; Figure 8
[11] 47
74
[10][11]
VBL(off)
battery-load turn-off voltage
VBG = 16 V; Figure 11
[12] 8
10
Overtemperature protection [10][11]
VBG = 35 V
15 20
Tj(th)
threshold junction temperature
[13] 150 170
Tj(th)(hys)
threshold junction temperature
hysteresis
-
10
Status [6][10]
VSG(CL) status-ground clamping voltage IS = 100 µA
5.5 7
VSG(L)
status-ground low voltage
IS = 100 µA; Figure 7
Tmb = −40 °C
-
-
Tmb = 25 °C
-
0.7
IS(off)
status leakage current
VSG = 5 V
Tmb = 150 °C
-
-
RS
status resistor
Tmb = 25 °C
-
0.1
connected externally; VSG = 5 V
[14] -
47
Max Unit
5.5 V
-
V
50 V
-
V
100 A
12 V
25 V
190 °C
-
°C
8.5 V
1
V
0.8 V
15
µA
1
µA
-
kΩ
[1] For a high-side switch, the load pin voltage goes negative with respect to ground during the turn-off of an inductive load.
[2] This is the current drawn from the supply when the input is LOW, and includes leakage current to the load.
[3] Defined as in ISO 10483-1. For comparison purposes only.
[4] The supply and input voltages for the RBLon tests are continuous. The specified pulse duration is tp = 300 µs, and refers only to the
applied load current.
[5] RG is a resistor incorporated internally in the package.
[6] 9 V ≤ VBG ≤ 16 V
[7] 9 V ≤ VBG ≤ 35 V. A low current load can be detected in the on-state.
[8] Undervoltage sensor causes the device to switch off and reset.
[9] Overvoltage sensor causes the device to switch off to protect the load.
[10] See Table 3 “Truth table”
[11] 5.5 V ≤ VBG ≤ 35 V
[12] The battery-to-load threshold voltage for short circuit is approximately proportional to the battery supply voltage.
[13] After cooling below the reset temperature the switch will resume normal operation.
[14] The status output is an open drain transistor and requires an external pull-up circuit to indicate a logic HIGH.
9397 750 10768
Product data
Rev. 01 — 17 March 2003
© Koninklijke Philips Electronics N.V. 2003. All rights reserved.
6 of 16