PDIUSBP11A
RECOMMENDED OPERATING CONDITIONS
SYMBOL
PARAMETER
CONDITIONS
VCC
VI
VAI/O
VO
Tamb
DC supply voltage
DC Input voltage range
DC input range for AI/O’s
DC output voltage range
Operating ambient temperature range in free air
See DC and AC characteristics
per device
LIMITS
MIN.
3.0
0
0
0
MAX.
3.6
5.5
VCC
VCC
–40
+85
UNIT
V
V
V
V
°C
ABSOLUTE MAXIMUM RATINGS1
In accordance with the Absolute Maximum Rating System (IEC 134) Voltages are referenced to GND (ground = 0V)
SYMBOL
PARAMETER
CONDITIONS
LIMITS
MIN
MAX
UNIT
VCC
DC supply voltage
–0.5
+6.5
V
Ilatchup Latchup current
VI < 0 or VI > VCC
–
200
mA
VI
DC input voltage
Note 2
–0.5
+5.5
V
VI/O
DC input voltage range for I/O’s
–0.5
VCC +0.5
V
VO
DC output voltage
Note 2
–0.5
VCC +0.5
V
ICC, IGND DC VCC or GND current
–
±100
mA
TSTO Storage temperature range
–60
+150
°C
PTOT Power dissipation per package
mW
NOTES:
1. Stresses beyond those listed may cause permanent damage to the device. These are stress ratings only and functional operation of the
device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to
absolute-maximum-rated conditions for extended periods may affect device reliability.
2. The input and output voltage ratings may be exceeded if the input and output clamp current ratings are observed.
1999 Jun 04