English
Language : 

SA56600-42 Datasheet, PDF (3/12 Pages) NXP Semiconductors – System reset for lithium battery backup
Philips Semiconductors
System reset for lithium battery back-up
Product data
SA56600-42
Part number marking
The package is marked with a four letter code in the first line to the
right of the logo. The first three letters designate the product. The
fourth letter, represented by ‘x’, is a date tracking code. The
remaining two or three lines of characters are internal manufacturing
codes.
PIN CONFIGURATION
GND 1
RESET 2
CS 3
VBATT 4
TOP VIEW
SO8
8 VCC
7Y
6 VOUT
5 CS
SL01278
Figure 2. Pin configuration.
Part number
SA56600-42
Marking
AAAx
PIN DESCRIPTION
PIN
SYMBOL
1
GND
2
RESET
3
CS
4
VBATT
5
CS
6
VOUT
7
Y
8
VCC
DESCRIPTION
Circuit ground for the device.
Asserted open collector output LOW whenever the VCC input source voltage falls below VS (4.2 V typical).
The open collector topology requires an external pull-up resistor.
Chip select HIGH output signal, asserted whenever the VCC input source voltage is above VS (4.2 V typical).
Can be used as a chip enable HIGH (CE) signal for system SRAM.
Positive polarity connection for lithium back-up battery.
Asserted chip select LOW output signal whenever the VCC input source voltage is above VS (4.2 V typical)
and Y is grounded. Can be used as a chip enable LOW (CE) signal for system SRAM.
Primary power with lithium battery back-up power for the protected system. Switch over to lithium battery
back-up operation occurs when VCC falls below VS.
Open Emitter input to microcontroller used to enable CS output (microcontroller controls CS function).
Primary input power source for device.
MAXIMUM RATINGS
SYMBOL
VCC(max)
VCC(op)
IO (VCC)
IO (VBATT)
Toper
Tstg
P
Power supply voltage
Operating voltage
Output current
Output current
Operating temperature
Storage temperature
Power dissipation
PARAMETER
RATING
–0.3 to +7.0
–0.3 to +7.0
80
200
–40 to +85
–40 to +125
250
UNIT
V
V
mA
µA
°C
°C
mW
2001 Jun 19
3