English
Language : 

PDIUSBP11 Datasheet, PDF (3/10 Pages) NXP Semiconductors – Universal Serial Bus transceiver
Philips Semiconductors
Universal Serial Bus transceiver
Preliminary specification
PDIUSBP11
RECOMMENDED OPERATING CONDITIONS
SYMBOL
PARAMETER
CONDITIONS
VCC
VI
VI/O
VO
Tamb
DC supply voltage
DC Input voltage range
DC input range for I/O’s
DC output voltage range
Operating ambient temperature range in
free air
See DC and AC characteristics
for individual device
LIMITS
MIN.
3.0
0
0
0
MAX.
3.6
5.5
VCC
VCC
0
+70
UNIT
V
V
V
V
°C
ABSOLUTE MAXIMUM RATINGS1, 2
In accordance with the Absolute Maximum Rating System (IEC 134) Voltages are referenced to GND (ground = 0V)
SYMBOL
PARAMETER
CONDITIONS
LIMITS
MIN
MAX
UNIT
VCC DC supply voltage
IIK
DC input diode current
VI
DC input voltage
VI/O DC input voltage range for I/O’s
IOK
DC output diode current
VO
DC output voltage
IO
DC output source or sink current for VP/VM,
RCV pins
VI < 0
Note 3
VO > VCC or VO < 0
Note 3
VO = 0 to VCC
–0.5
+6.5
V
–
–50
mA
–0.5
+5.5
V
–0.5
VCC +0.5
V
–
"50
mA
–0.5
VCC +0.5
V
–
"15
mA
IO
DC output source or sink current for D+/D–
pins
VO = 0 to VCC
–
"50
mA
IGND, ICC DC VCC or GND current
–
"100
mA
Tstg
Storage temperature range
–60
+150
°C
Ptot
Power dissipation per package
mW
NOTES:
1. Stresses beyond those listed may cause permanent damage to the device. These are stress ratings only and functional operation of the
device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to
absolute-maximum-rated conditions for extended periods may affect device reliability.
2. The performance capability of a high-performance integrated circuit in conjunction with its thermal environment can create junction
temperatures which are detrimental to reliability. The maximum junction temperature of this integrated circuit should not exceed 150°C.
3. The input and output voltage ratings may be exceeded if the input and output clamp current ratings are observed.
1997 Sep 16