English
Language : 

HC2-HP-DC12V Datasheet, PDF (7/15 Pages) Panasonic Semiconductor – Relay for control panel of 1A to 10A (1c/2c/3c/4c)
HC
RATING
1. Standard type
1) Coil data
(1) AC coils (50/60Hz)
Type
Standard
Nominal coil Pick-up voltage
voltage
(at 20°C 68°F)
6V AC
12V AC
24V AC
48V AC
100/110V AC
110/120V AC
200/220V AC
80%V or less of
nominal voltage
(Initial)
Drop-out
voltage
(at 20°C 68°F)
30%V or more
of nominal
voltage
(Initial)
Nominal coil current
[±20%] (at 20°C 68°F)
50Hz
60Hz
224mA
111mA
56mA
28mA
13.4/14.7mA
12.2/13.5mA
6.7/7.4mA
200mA
100mA
50mA
25mA
12/13.2mA
10.9/11.9mA
6/6.6mA
Coil inductance
N.C.
condition
0.078H
0.312H
1.243H
4.974H
23.75H
27.19H
85.98H
N.O.
condition
0.074H
0.295H
1.181H
4.145H
20.63H
25.57H
81.76H
Nominal operating
power
50Hz
60Hz
Max. applied
voltage
(at 70°C 158°F)
1.3VA
1.2VA
110%V of
nominal voltage
Notes: 1. The relay operates in a range of 80% to 110% V of the voltage rating, but ideally, in consideration of temporary voltage fluctuations, it should be operated at the
rated voltage. In particular, for AC operation, if the applied voltage drops to 80% V or more below the rated voltage, humming will occur and a large current will flow
leading possibly to coil burnout.
2. The maximum applied voltage is the maximum voltage fluctuation value for the coil power supply. This value is not a permissible value for continuous operation.
(This value differs depending on the ambient temperature. Please contact us for details.)
(2) DC coils
Type
Standard
Nominal coil
voltage
6V DC
12V DC
24V DC
48V DC
100/110V DC
Pick-up voltage
(at 20°C 68°F)
80%V or less of
nominal voltage
(Initial)
Drop-out voltage
(at 20°C 68°F)
10%V or more of
nominal voltage
(Initial)
Nominal coil current
[±10%]
(at 20°C 68°F)
150mA
75mA
37mA
18.5mA
10/11mA
Coil resistance
[±10%]
(at 20°C 68°F)
40Ω
160Ω
650Ω
2,600Ω
10,000Ω
Nominal operating Max. applied voltage
power
(at 70°C 158°F)
0.9W
1.0W
110%V of
nominal voltage
Notes: 1. The coil resistance for DC operation is the value measured when the coil temperature is 20°C 68°F. Compensate ±0.4% for every ±1°C change in temperature.
2. The relay operates in a range of 80% to 110% V of the voltage rating, but ideally, in consideration of temporary voltage fluctuations, it should be operated at the
rated voltage.
3. For use with 200 V DC, connect a 10 KΩ (5W) resistor, in series, to the 100 V DC relay.
4. The maximum applied voltage is the maximum voltage fluctuation value for the coil power supply. This value is not a permissible value for continuous operation.
(This value differs depending on the ambient temperature. Please contact us for details.)
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
ASCTB4E 201302-T