English
Language : 

E2C-JC4CH Datasheet, PDF (6/23 Pages) Omron Electronics LLC – Separate Amplifier Sensor with Sensitivity Adjustment
Cable Lengths for Sensor-Amplifier Unit Combinations
E2C/E2C-H
Standard Models
Sensor
Amplifier Units
E2C-CR8A
E2C-CR8B
E2C-X1A
E2C-C1A
E2C-
X1R5A
E2C-GE4A
E2C-GF4A
Restricted to 3 m.
E2C-WH4A
Restricted to 3 m or 5 m.
Set cable length switch to desired position. *
E2C-JC4AP
1 to 3 m: Short cable length terminals *
3 to 5 m: Open cable length terminals *
E2C-JC4A
Restricted to 3 m.
E2C-AM4A
E2C-AK4A
0 to 5 m
Set cable length switch to desired position. *
E2C-X2A
---
---
---
E2C-X5A
---
---
---
E2C-X10A
---
---
---
E2C-
C20MA
---
---
---
---
---
---
---
---
---
0 to 10 m
Set cable length switch to desired position. *
Note: The standard cable length is 3 m. Models with 5-m or 10-m are manufactured upon order.
* Refer to page 14 for the operation of cable length switching.
Heat-resistant Models
Sensor
Amplifier Units
E2C-JC4CH
E2C-JC4DH
E2C-JC4EH
E2C-X1R5AH
E2C-X2AH
E2C-X5AH
Set 3 m/5 m cable length switch to desired position.
Note: The standard cable length is 3 m. Models with 5-m are manufactured upon order.
Self-diagnostic Function
The self-diagnostic output transistor will turn ON in the following cases. (The output will turn ON for any of these conditions individually.)
(1) Sensor open circuit: Transistor will turn ON the instance there is an open circuit for the Sensor (including the cable).
Sensor Open Circuit
Sensor Connected
Sensing distance:
Approx. 107%
Set distance: 100%
Approx. 97%
Present
Sensing object None
Control output
(NO)
ON
OFF
Self-diagnostic ON
output
OFF
Detection indicator ON
(red)
OFF
Stability indicator ON
(green)
OFF
Red
Red
Green
Open Open circuit
circuit eliminated
Open
circuit
Open circuit
eliminated
Control output
(NO)
ON
OFF
Self-diagnostic ON
output
OFF
Detection indicator ON
(red)
OFF
Stability indicator ON
(green)
OFF
0.3 s min.
*
Green
0.3 s min.
*
Red
Green
Time
Green
Note: When the E2C-X2A Sensor is used, 93% is 96% and 107% is 104%.
* The self-diagnostic output may turn ON if the sensing objects moves a low
speed. In actual application, include an ON-delay timer circuit or other
suitable measure.
(2) Detection: The output will turn ON if a sensing object is within 93% to 100% of the sensing distance continuously for 0.3 s or longer (e.g.,
for sensing object position offset).
(3) No detection: The output will turn ON if a sensing object is within 100% to 107% of the sensing distance continuously for 0.3 s or longer (e.g.,
when background is influencing detection).
Indicators
• The detection indicator lights when a sensing object approaches the
sensing distance to indicate that a sensing object has been detected.
• The stability indicator lights when the sensing object approaches within
93% of the sensing distance or moves away from 107% of the sensing
distance to indicate a stable sensing or non-sensing condition.
Detection
indicator (red)
Stability indicator
(green)
OFF
ON
OFF
Set distance × Approx. 1.07*
Set distance
Set distance × Approx. 0.93*
ON
ON
* When the E2C-X2A Sensor is used,
107% is 104% and 93% is 96%.