Load Connections
Model
Load
E2C-JC4A, E2C-JC4@H
DC load
• Relay
• Solenoid
Current-sink-
ing load
• Program-
mable
Controller
• Sensor
Controller
Brown
Load
Black
Blue
Voltage load
(logic circuit)
Brown
Black
Blue
4.7 k
Interface circuits
12 to 24 VDC
+V
To next stage
0V
Logic circuit
E2C/E2C-H
Model
Load
DC load
• Relay
• Solenoid
E2C-WH4A
0V
5
PNP
Output
7
Load *
(12 to 24 V)
6
NPN
output
Load *
IL
8 200 mA max.
Solid-state
load
• Program-
mable
Controller
• Sensor
Controller
(S3D8)
Voltage load
(logic circuit)
* Use 40 V maximum when connecting the load to a
separate power supply.
0 V (12 to 24 V)
56
Load *
NPN output
7
8
IL
200 mA max.
* For a current-sourcing load, connect the PNP output.
0V
5
PNP
output
7
(12 to 24 V)
6
8
Load
Model
DC load
• Relay
• Solenoid
Solid-state load
• Programma-
ble Control-
ler
• Sensor
Controller
E2C-GE4A
Note: The E2C-WH4A supports both NPN and PNP open-collector output. It
can be connected to a wide variety of load types and power polarities.
9
Amplifier Unit
14
13
Load
Voltage load
(logic circuit)
Remarks
9
Amplifier Unit
14
13
IC: 20 mA max.
Tr HFE: 50 mA max.
VCED: 30 V min.
4.7 K ¼W
4.7K ¼W VV : 3V
0.0022 µ
Tr
4.7 K
¼W
Interface circuits
12 to 24 V
+V
To next stage
−V (0 V)
Solid-state circuit
When connecting to a CMOS IC or TLL, provide an interface circuit as shown
above and connect to the solid-state circuit in the next stage.
11