AMIS−30623
DC PARAMETERS
The DC parameters are guaranteed overtemperature and VBB in the operating range, unless otherwise specified. Convention:
currents flowing into the circuit are defined as positive.
Table 5. DC PARAMETERS
Symbol Pin(s)
Parameter
Test Conditions
Min
Typ
Max
Unit
MOTORDRIVER
IMSmax,Peak
Max current through motor
coil in normal operation
VBB = 14 V
800
mA
IMSmax,RMS
Max rms current through
coil in normal operation
VBB = 14 V
570
mA
IMSabs
Absolute error on coil
current (Note 8)
VBB = 14 V
−10
10
%
IMSrel
MOTXP
MOTXN Matching of X & Y
MOTYP coil currents
VBB = 14 V
−7
0
7
%
RDS(on)
MOTYN On resistance for each
motor pin at IMSmax
(Note 9)
VBB = 12 V, Tj = 50°C
VBB = 8 V, Tj = 50°C
0.50
1
W
0.55
1
W
VBB = 12 V, Tj = 150°C
0.70
1
W
VBB = 8 V, Tj = 150°C
0.85
1
W
IMSL
Pulldown current
HiZ mode, VBB = 7.8 V
2
mA
LIN TRANSMITTER
Ibus_off
Dominant state, driver off Vbus = 0 V, VBB = 8 V & 18 V
−1
Ibus_off
Recessive state, driver off Vbus = Vbat, VBB = 8 V & 18 V
LIN
Ibus_lim
Current limitation
VBB = 8 V & 18 V
50
Rslave
Pullup resistance
VBB = 8 V & 18 V
20
LIN RECEIVER
mA
20
mA
75
130
mA
30
47
kW
Vbus_dom
Receiver dominant state
Vbus_rec
LIN Receiver recessive state
Vbus_hys
Receiver hysteresis
THERMAL WARNING & SHUTDOWN
VBB = 8 V & 18 V
VBB = 8 V & 18 V
VBB = 8 V & 18 V
0
0.6 * VBB
0.05 * VBB
0.4 * VBB
V
VBB
V
0.175 * VBB V
Ttw
Thermal warning
(Notes 10 and 11)
138
145
152
°C
Ttsd
Thermal shutdown (Note 12)
Tlow
Low temperature warning
(Note 12)
Ttw + 10
°C
Ttw − 155
°C
SUPPLY AND VOLTAGE REGULATOR
VbbOTP
Supply voltage for OTP
zapping (Note 13)
9.0
10.0
V
UV1
UV2
Ibat
Ibat_s
Stop voltage high threshold
Stop voltage low threshold
VBB
Total current consumption
Sleep mode current
consumption
Unloaded outputs
VBB = 29 V
VBB = 8 V & 18 V
7.8
8.4
8.9
V
7.1
7.5
8.0
V
3.50
10.0
mA
50
100
mA
8. Tested in production for 800 mA, 400 mA, 200 mA and 100 mA current settings for both X and Y coil.
9. Not measured in production. Guaranteed by design.
10. Parameter guaranteed by trimming relevant OTP’s in production test at 143°C (±5°C) and VBB = 14 V.
11. No more than 100 cumulated hours in life time above Tw.
12. Thermal shutdown and low temperature warning are derived from thermal warning. Guaranteed by design.
13. A buffer capacitor of minimum 100 mF is needed between VBB and GND. Short connections to the power supply are recommended.