AMIS30623C623BRG Datasheet, PDF (13/61 Pages) ON Semiconductor – Micro-stepping Motor Driver | |||
|
◁ |
AMISâ30623
Position Ranges
A position is coded by using the binary twoâs complement format. According to the positioning commands used and to the
chosen stepping mode, the position range will be as shown in the following table.
Table 11. POSITION RANGE
Command
Stepping Mode
Position Range
Full Range Excursion
Number of Bits
Halfâstepping
â4096 to +4095
8192 halfâsteps
13
1/4th microâstepping
â8192 to +8191
16384 microâsteps
14
SetPosition
1/8th microâstepping
â16384 to +16383
32768 microâsteps
15
1/16th microâstepping
â32768 to +32767
65536 microâsteps
16
SetPositionShort
Halfâstepping
â1024 to +1023
2048 halfâsteps
11
When using the command SetPosition, although
coded on 16 bits, the position word will have to be shifted to
the left by a certain number of bits, according to the stepping
mode.
Secure Position
A secure position can be programmed. It is coded in
11âbits, thus having a lower resolution than normal
positions, as shown in the following table. See also
command GotoSecurePosition and LIN lost behavior.
Table 12. SECURE POSITION
Stepping Mode
Secure Position Resolution
Halfâstepping
4 halfâsteps
1/4th microâstepping
8 microâsteps (1/4th)
1/8th microâstepping
1/16th microâstepping
16 microâsteps (1/8th)
32 microâsteps (1/16th)
Important
NOTES: The secure position is disabled in case the programmed value is the reserved code â10000000000â (0x400 or most negative
position).
The resolution of the secure position is limited to 9 bit at startâup. The OTP register is copied in RAM as illustrated below. The
RAM bits SecPos1 and SecPos0 are set to 0.
SecPos10
SecPos9
SecPos8
SecPos2
SecPos1
SecPos0
RAM
SecPos10
SecPos9
SecPos8
SecPos2
FailSafe
SleepEn
OTP
Shaft
A shaft bit, which can be programmed in OTP or with
command SetMotorParam, defines whether a positive
motion is a clockwise (CW) or counterâclockwise rotation
(CCW) (an outer or an inner motion for linear actuators):
⢠Shaft = 0 â MOTXP is used as positive pin of the X
coil, while MOTXN is the negative one.
⢠Shaft = 1 â opposite situation
Exception: in RunVelocity mode, the shaft bit has no
function. In this mode the rotational direction is always CW
or CCW, which is only determined by the motor wiring.
STRUCTURAL DESCRIPTION
See also the Block Diagram in Figure 1.
Stepper Motordriver
The Motordriver receives the control signals from the
control logic. The main features are:
⢠Two Hâbridges, designed to drive a stepper motor with
two separated coils. Each coil (X and Y) is driven by
one Hâbridge, and the driver controls the currents
flowing through the coils. The rotational position of the
rotor, in unloaded condition, is defined by the ratio of
current flowing in X and Y. The torque of the stepper
motor when unloaded is controlled by the magnitude of
the currents in X and Y.
⢠The control block for the Hâbridges, including the
PWM control, the synchronous rectification and the
internal current sensing circuitry.
http://onsemi.com
13
|
▷ |