Table 2. ABSOLUTE MAXIMUM RATINGS
Parameter
Rating
Units
Operating Supply Voltage (VP − VN)
Operating Temperature Range
6.0
V
–40 to +85
°C
Storage Temperature Range
–65 to +150
°C
DC Voltage at any channel input
(VN − 0.5) to (VP + 0.5)
V
Stresses exceeding those listed in the Maximum Ratings table may damage the device. If any of these limits are exceeded, device functionality
should not be assumed, damage may occur and reliability may be affected.
Table 3. STANDARD OPERATING CONDITIONS
Parameter
Rating
Units
Operating Temperature Range
–40 to +85
°C
Package Power Rating
SOT23−3, SOT143−4, SC−74, and SC70−6 Packages
MSOP−10 Package
mW
225
400
Functional operation above the stresses listed in the Recommended Operating Ranges is not implied. Extended exposure to stresses beyond
the Recommended Operating Ranges limits may affect device reliability.
Table 4. ELECTRICAL OPERATING CHARACTERISTICS (Note1)
Symbol
Parameter
Conditions
Min Typ Max Units
VP
Operating Supply Voltage (VP−VN)
IP
Operating Supply Current
VF
Diode Forward Voltage
Top Diode
Bottom Diode
(VP−VN) = 3.3 V
IF = 8 mA; TA = 25°C
3.3 5.5
V
8.0 mA
V
0.60 0.80 0.95
0.60 0.80 0.95
ILEAK
CIN
Channel Leakage Current
Channel Input Capacitance
TA = 25°C; VP = 5 V, VN = 0 V
At 1 MHz, VP = 3.3 V, VN = 0 V, VIN = 1.65 V
(Note 2)
0.1 1.0 mA
0.85 1.2 pF
DCIN
Channel Input Capacitance Matching
At 1 MHz, VP = 3.3 V, VN = 0 V, VIN = 1.65 V
0.02
pF
(Note 2)
VESD
VCL
ESD Protection − Peak Discharge
Voltage at any channel input, in system
Contact discharge per
IEC 61000−4−2 standard
Channel Clamp Voltage
Positive Transients
Negative Transients
TA = 25°C (Notes 2 and 3)
TA = 25°C, IPP = 1A, tP = 8/20 mS
(Note 2)
kV
8
V
+10
–1.7
RDYN
Dynamic Resistance
Positive Transients
Negative Transients
IPP = 1A, tP = 8/20 mS
Any I/O pin to Ground
(Note 2)
W
0.9
0.5
Product parametric performance is indicated in the Electrical Characteristics for the listed test conditions, unless otherwise noted. Product
performance may not be indicated by the Electrical Characteristics if operated under different conditions.
1. All parameters specified at TA = –40°C to +85°C unless otherwise noted.
2. Standard IEC 61000−4−2 with CDischarge = 150 pF, RDischarge = 330 W, VP = 3.3 V, VN grounded.
3. These measurements performed with no external capacitor on VP (VP floating).
www.onsemi.com