English
Language : 

AR023ZM Datasheet, PDF (31/35 Pages) ON Semiconductor – 1/2.7-Inch 2.1 Mp/Full HD Digital Image Sensor
ON Semiconductor Confidential and Proprietary
AR023ZM: 1/2.7-Inch 2.1 Mp/Full HD Digital Image Sensor
Power-On Reset and Standby Timing
Power-On Reset and Standby Timing
Power-Up Sequence
The recommended power-up sequence for the AR023ZM is shown in Figure 11. The
available power supplies (VDD_IO, VDD, VDD_SLVS, VDD_PLL, VAA, VAA_PIX) must have
the separation specified below.
1. Turn on VDD_PLL power supply.
2. After 100s, turn on VAA and VAA_PIX power supply.
3. After 100s, turn on VDD_IO power supply.
4. After 100s, turn on VDD power supply.
5. After 100s, turn on VDD_SLVS power supply.
6. After the last power supply is stable, enable EXTCLK.
7. Assert RESET_BAR for at least 1ms. The parallel interface will be tri-stated during this
time.
8. Wait 150000 EXTCLKs (for internal initialization into software standby.
9. Configure PLL, output, and image settings to desired values.
10. Wait 1ms for the PLL to lock.
11. Set streaming mode (R0x301a[2] = 1).
Figure 11: Power Up
VDD_PLL (2.8)
VAA_PIX
VAA (2.8)
t0
t1
VDD_IO (1.8/2.8)
t2
VDD (1.8)
t3
VDD_SLVS (0.4)
EXTCLK
RESET_BAR
tx
t4
Hard Reset
t5
Internal
Initialization
Software
Standby
t6
PLL Lock
Streaming
AR0230CS_DS Rev. 4 Pub. 8/15 EN
31
©Semiconductor Components Industries, LLC, 2015.