English
Language : 

AMIS-30542 Datasheet, PDF (27/29 Pages) ON Semiconductor – AMIS-30542 Micro-Stepping Motor Driver
AMIS−30542
Table 17. SPI STATUS FLAGS OVERVIEW
Mnemonic
Flag
Length
(bit)
Related
SPI Register
Comment
Reset
State
CPFail Charge pump failure
1
Status Register 0 ‘0’ = no failure
‘0’
‘1’ = failure: indicates that the charge pump does
not reach the required voltage level. Note 1
MSP[6:0] Micro−step position
7
Status Register 3 Translator micro step position
‘0000000’
OPENX OPEN Coil X
1
Status Register 0 ‘1’ = Open coil detected
‘0’
OPENY OPEN Coil Y
1
Status Register 0 ‘1’ = Open coil detected
‘0’
OVCXNB OVer Current on X
1
Status Register 1 ‘0’ = no failure
‘0’
H−bridge; MOTXN
‘1’ = failure: indicates that over current is detected
terminal; Bottom
at bottom transistor XN−terminal
tran.
OVCXNT OVer Current on X
1
Status Register 1 ‘0’ = no failure
‘0’
H−bridge; MOTXN
‘1’ = failure: indicates that over current is detected
terminal; Top transist.
at top transistor XN−terminal
OVCXPB OVer Current on X
1
Status Register 1 ‘0’ = no failure
‘0’
H−bridge; MOTXP
‘1’ = failure: indicates that over current is detected
terminal; Bottom
at bottom transistor XP−terminal
tran.
OVCXPT OVer Current on X
1
Status Register 1 ‘0’ = no failure
‘0’
H−bridge; MOTXP
‘1’ = failure: indicates that over current is detected
terminal; Top transist.
at top transistor XP−terminal
OVCYNB OVer Current on Y
1
Status Register 2 ‘0’ = no failure
‘0’
H−bridge; MOTYN
‘1’ = failure: indicates that over current is detected
terminal; Bottom tran.
at bottom transistor YN−terminal
OVCYNT OVer Current on Y
1
Status Register 2 ‘0’ = no failure
‘0’
H−bridge; MOTYN
‘1’ = failure: indicates that over current is detected
terminal; Top transist.
at top transistor YN−terminal
OVCYPB OVer Current on Y
1
Status Register 2 ‘0’ = no failure
‘0’
H−bridge; MOTYP
‘1’ = failure: indicates that over current is detected
terminal; Bottom
at bottom transistor YP−terminal
tran.
OVCYPT OVer Current on Y
1
Status Register 2 ‘0’ = no failure
‘0’
H−bridge; MOTYP
‘1’ = failure: indicates that over current is detected
terminal; Top transist.
at top transistor YP−terminal
TSD Thermal shutdown
1
Status Register 2
‘0’
TW
Thermal warning
1
Status Register 0
‘0’
WD
Watchdog event
1
Status Register 0 ‘1’ = watchdog reset after time−out
‘0’
NOTE: WD − This bit indicates that the watchdog timer has not been cleared properly. If the master reads that WD is set to “1” after reset,
it means that a watchdog reset occurred (warm boot) instead of POR (cold boot). WD bit will be cleared only when the master
writes “0” to WDEN bit.
Table 18. ORDERING INFORMATION
Part No.
Peak Current
Temperature
Range
Package
Shipping†
AMIS30542C5421RG
3200 mA
−40°C to 125°C
NQFP−32 (7 x 7 mm)
(Pb−Free)
Units / Tubes
AMIS30542C54212G
3200 mA
−40°C to 125°C
NQFP−32 (7 x 7 mm)
(Pb−Free)
Tape & Reel
†For information on tape and reel specifications, including part orientation and tape sizes, please refer to our Tape and Reel Packaging
Specifications Brochure, BRD8011/D.
http://onsemi.com
27