AMIS-30542 Datasheet, PDF (12/29 Pages) ON Semiconductor – AMIS-30542 Micro-Stepping Motor Driver | |||
|
◁ |
AMISâ30542
Automatic Duty Cycle Adaptation
In case the supply voltage is lower than 2*Bemf, then the
duty cycle of the PWM is adapted automatically to > 50%
to maintain the requested average current in the coils. This
process is completely automatic and requires no additional
parameters for operation. The overâall currentâripple is
divided by two if PWM frequency is doubled (see Table 14
SPI Control Parameter Overview PWMF)
Icoil
Duty Cycle
< 50%
Duty Cycle > 50%
Duty Cycle < 50%
Actual value
Set value
t
TPWM
Figure 9. Automatic Duty Cycle Adaption
Step Translator and Step Mode
The step translator provides the control of the motor by
means of SPI register Stepmode: SM[2:0], SPI register
DIRCNTRL and input pins DIR and NXT. It is translating
consecutive steps in corresponding currents in both motor
coils for a given step mode.
One out of seven possible stepping modes can be selected
through SPIâbits SM[2:0] (see Table 14 SPI Control
Parameter Overview ) After powerâon or hard reset, the
coilâcurrent translator is set to the default 1/32
microâstepping at position â0â. Upon changing the step
mode, the translator jumps to position 0* of the
corresponding stepping mode. When remaining in the same
step mode, subsequent translator positions are all in the same
column and increased or decreased with 1. Table 10 lists the
output current vs. the translator position.
As shown in Figure 10 the output currentâpairs can be
projected approximately on a circle in the (Ix, Iy) plane.
There are, however, two exceptions: uncompensated half
step and full step. In these step modes the currents are not
regulated to a fraction of Imax but are in all intermediate steps
regulated at 100%. In the (Ix, Iy) plane the currentâpairs are
projected on a square. Table 9 lists the output current vs. the
translator position for these cases.
Table 9. SQUARE TRANSLATOR TABLE FOR FULL STEP AND UNCOMPENSATED HALF STEP
Stepmode ( SM[2:0] )
101
110
% of Imax
MSP[6:0]
Uncompensated Half Step
Full Step
Coil x
Coil y
000 0000
0*
â
0
100
001 0000
1
1
100
100
010 0000
2
â
100
0
011 0000
3
2
100
â100
100 0000
4
â
0
â100
101 0000
5
3
â100
â100
110 0000
6
â
â100
0
111 0000
7
0
â100
100
http://onsemi.com
12
|
▷ |