English
Language : 

AMIS-30532 Datasheet, PDF (27/29 Pages) ON Semiconductor – Micro-Stepping Motor Driver
AMIS--30532
Table 17. SPI STATUS FLAGS OVERVIEW
Mnemonic
Flag
Length
(bit)
CPFail Charge pump failure
1
Related SPI Register
Status Register 0
Comment
‘0’ = no failure
‘1’ = failure: indicates that the charge pump does
not reach the required voltage level. Note 1
Reset
State
‘0’
MSP[6:0] Micro--step position
7
OPENX OPEN Coil X
1
OPENY OPEN Coil Y
1
OVCXNB OVer Current on X
1
H--bridge; MOTXN
terminal; Bottom
tran.
OVCXNT OVer Current on X
1
H--bridge; MOTXN
terminal; Top
transist.
Status Register 3
Status Register 0
Status Register 0
Status Register 1
Status Register 1
Translator micro step position
‘1’ = Open coil detected
‘1’ = Open coil detected
‘0’ = no failure
‘1’ = failure: indicates that over current is
detected at bottom transistor XN--terminal
‘0’ = no failure
‘1’ = failure: indicates that over current is
detected at top transistor XN--terminal
‘0000000’
‘0’
‘0’
‘0’
‘0’
OVCXPB OVer Current on X
1
Status Register 1 ‘0’ = no failure
‘0’
H--bridge; MOTXP
‘1’ = failure: indicates that over current is
terminal; Bottom
detected at bottom transistor XP--terminal
tran.
OVCXPT OVer Current on X
1
Status Register 1 ‘0’ = no failure
‘0’
H--bridge; MOTXP
‘1’ = failure: indicates that over current is
terminal; Top
detected at top transistor XP--terminal
transist.
OVCYNB OVer Current on Y
1
Status Register 2 ‘0’ = no failure
‘0’
H--bridge; MOTYN
‘1’ = failure: indicates that over current is
terminal; Bottom
detected at bottom transistor YN--terminal
tran.
OVCYNT OVer Current on Y
1
Status Register 2 ‘0’ = no failure
‘0’
H--bridge; MOTYN
‘1’ = failure: indicates that over current is
terminal; Top
detected at top transistor YN--terminal
transist.
OVCYPB OVer Current on Y
1
Status Register 2 ‘0’ = no failure
‘0’
H--bridge; MOTYP
‘1’ = failure: indicates that over current is
terminal; Bottom
detected at bottom transistor YP--terminal
tran.
OVCYPT OVer Current on Y
1
Status Register 2 ‘0’ = no failure
‘0’
H--bridge; MOTYP
‘1’ = failure: indicates that over current is
terminal; Top
detected at top transistor YP--terminal
transist.
TSD
Thermal shutdown
1
Status Register 2
‘0’
TW
Thermal warning
1
Status Register 0
‘0’
WD
Watchdog event
1
Status Register 0 ‘1’ = watchdog reset after time--out
‘0’
NOTE: WD -- This bit indicates that the watchdog timer has not been cleared properly. If the master reads that WD is set to “1” after reset,
it means that a watchdog reset occurred (warm boot) instead of POR (cold boot). WD bit will be cleared only when the master
writes “0” to WDEN bit.
Table 18. ORDERING INFORMATION
Part No.
Peak Current
Temperature
Range
Package
Shipping†
AMIS30532C5321RG
1600 mA
--40°C to 125°C
NQFP--32 (7 x 7 mm)
(Pb--Free)
Units / Tubes
AMIS30532C53212G
1600 mA
--40°C to 125°C
NQFP--32 (7 x 7 mm)
(Pb--Free)
Tape & Reel
†For information on tape and reel specifications, including part orientation and tape sizes, please refer to our Tape and Reel Packaging
Specifications Brochure, BRD8011/D.
http://onsemi.com
27