English
Language : 

E3XA51 Datasheet, PDF (9/17 Pages) Omron Electronics LLC – Fiber-Optic Photoelectric Sensor
E3X
E3X
s LIGHT AXIS ADJUSTMENT WITH FLASHING FUNCTION
E3X-A❏❏/-F❏❏/-VG❏❏
1. Set the mode selector to SET.
2. Adjust the light axis by moving the fiber with
the light flashing.
Improper Light Axis
Proper Light Axis
Mode Selector
Flashing
Light axis
adjusted
Light ON with
no flashing
3. Set the mode selector to L-ON or D-ON after the
light axis is adjusted.
s SELF-DIAGNOSTIC FUNCTION
With this function, the E3X checks changes in environment
conditions (especially a change in the ambient temperature) and
self-diagnoses the resistance against the changes. The result is
shown by the indicators or an output signal.
Stable Operation Indicator
(Green Indicator)
Light Reception Indicator
(Red Indicator)
Displays
q Stable Operation Indicator: Changes in environmental
conditions (changes in the ambient temperature, the
operating voltage, or the volume of dust) are checked and
the resistance against them are self-diagnosed. The result
is shown via the indicator.
q Light Reception Indicator: The amount of light received is
shown by this indicator.
Output:
q The resistance against changes in environmental
conditions is shown by the indicator and the result is
output.
Amount of
light
1.2
1
0.8
Operating level x 1.2
Operating level
Operating level x 0.8
Control output
(L, ON)
Self-diagnostic
output*
ON
OFF
ON
OFF
Indicator Green
0.3 s min.
Red
Green
0.3 s min.
Green
Tip of the fiber connected
to the light source side in
the SET mode
Flashing
light ON
Flashing
*If the self-diagnostic output is ON when the sensing object is
moving at low speed, use the E3X with an ON-delay timer circuit.
10
10