Dimensions
■ Terminals
Note: Unless otherwise specified, all units are in millimeters and a tolerance of ±0.4 mm applies to all dimensions
Terminal
type
COM
Terminal
dimensions
Solder Terminal
(A)
(5.5)
(6.5)
2.9
t = 0.5 (10)
Three, solder terminals
6.35
3.2 (see note)
4.75±0.1
2.4 dia. 1.6 dia.
Note: Indicates the length to the
center of the 1.6-dia. holes
Quick-connect Terminal
(#187) (C2)
(5.5)
(6.5)
2.9
t = 0.5 (10)
Three, quick-connect
terminals (#187)
6.35
3.2
4.75±0.1
1.6-dia. terminal hole
Quick-connect Terminal
(#250) (C)
(4.9)
(7.7)
3.2
(12.0)
t = 0.8 Three, quick-connect
terminals (#250)
8
3.95
6.35±0.1
1.65-dia. terminal hole
Quick-connect RAST5
Terminals (#250)(C6)
16.8
(3.5)
5 15.2
12.8
t=0.8
Three quick connect
terminals (#250)
4.5
6.3±0.1
1.75-dia. terminal hole
Note: The table above is for the SPDT contact specifications. Two terminals will be available for SPST-NO or SPST-NC contact specifications. For
terminal positions, refer to the above Contact Form.
■ Mounting Holes
All switches may be panel mounted using M3 mounting screws with
plane washers or spring washers to securely mount the switch.
Tighten the screws to a torque of 0.39 to 0.59 N·m.
Two, 3.1-dia. mounting holes or
M3 screw holes
10.3±0.1
22.2±0.1
■ Dimensions and Operating Characteristics
Note: 1. Unless otherwise specified, all units are in millimeters and a tolerance of ±0.4 mm applies to all dimensions
2. The following illustrations and drawings are for quick-connect terminals (#187) (terminals C2). D3V models also incorporate terminals A, C, and
C6, which are omitted from the following drawings. Refer to Terminals section for the dimensions of these terminals.
3. The @ in the model number is for the terminal code.
4. The Δ in the model number is for combinations of the enclosure material, the mounting hole size and the special code as indicated in the Model
Number Legend and Available Combinations tables. The hole size in the following illustrations of models with a suffix “K” in the Δ is 2.9 mm.
5. The operating characteristics are for operation in the A direction ( ).
Plunger Models
D3V-21G-1@4A-Δ
D3V-16-1@5-Δ
D3V-11-1@5-Δ
D3V-11-1@4-Δ
D3V-6-1@4-Δ
D3V-6G-1@3-Δ
D3V-01-1@2-Δ
D3V-01-1@3-Δ
A
t=0.5
Three, quick-connect
terminals (#187)
Model
OF max.
RF min.
PT max.
OT min.
MD max.
OP
D3V-21G-1@4A-Δ
125 gf
20 gf
1.2 mm
1.0 mm
0.3 mm
D3V-16-1@5-Δ
D3V-11-1@5-Δ
D3V-11-1@4-Δ
D3V-6-1@4-Δ
D3V-6G-1@3-Δ
200 gf
50 gf
100 gf
15 gf
50 gf
5 gf
1.2 mm
1.0 mm
0.4 mm (F gap type) or 0.3 mm (G gap type)
14.7±0.4 mm
D3V-01-1@3-Δ
D3V-01-1@2-Δ
50 gf
5 gf
1.2 mm
1.0 mm
0.4 mm
25 gf
3 gf
80