English
Language : 

D3V Datasheet, PDF (7/18 Pages) Omron Electronics LLC – Miniature Basic Switch
■ Characteristics
Operating speed
Operating frequency
Insulation resistance
Contact resistance
0.1 mm to 1 m/s (plunger models)
Mechanical: 600 operations/min
Electrical: 60 operations/min
100 MΩ min. (at 500 VDC)
D3V-21:
50 mΩ max.
D3V-16, D3V-11, D3V-6:
30 mΩ max.
D3V-01, 50 gf versions:
50 mΩ max.
Dielectric strength (see note 2)
Vibration resistance (see note 3)
Shock resistance (see note 3)
Life expectancy
25 gf versions:
100 mΩ max.
1,000 VAC, 50/60 Hz for 1 min between terminals of the same polarity
2,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and ground, and between
each terminal and non-current-carrying metal parts
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Destruction: 400 m/s2 (approx. 40G) max.
Malfunction: 100 m/s2 (approx. 10G) max.
Mechanical: 10,000,000 operations min.
Electrical: D3V-21:
50,000 operations min.
D3V-16:
100,000 operations min.
D3V-11:
200,000 operations min.
D3V-6, D3V-01: 500,000 operations min.
Degree of protection
IEC IP40
Degree of protection against electric shock Class I
Proof tracking index (PTI)
250 (High Temperature type with suffix “-T”: 175)
Ambient operating temperature
D3V-21: -25°C to 85°C with no icing
D3V-16: -25°C to 105°C (High Temperature type “H”: -25°C to 125°C) with no icing
D3V-11: -25°C to 105°C (High Temperature types “H”: -25°C to 125°C, “T”: -25°C to 155°C) with no icing
D3V-6: -25°C to 105°C (High Temperature types “H”: -25°C to 125°C, “T”: -25°C to 200°C) with no icing
Ambient operating humidity
Weight
D3V-01: -25°C to 85°C (High Temperature type “T”: -25°C to 200°C) with no icing
85% max. (for 5°C to 35°C)
Approx. 6.2 g (plunger models)
Note: 1. Data shown are of initial value.
2. The dielectric strength values shown in the table are for models with a Separator.
3. For plunger models, the above values apply for use at both the free position and total travel position. For lever models, they apply at the
total travel position.
4. For testing conditions, contact your OMRON sales representative.
■ Contact Specifications
Contact
Item
Inrush current
Minimum applicable load
Specification
Material
Gap
(standard value)
NC
NO
D3V-21
0.5 mm
50 A max.
D3V-16
D3V-11
Rivet
Silver alloy
D3V-6
1 mm (F gap type) or 0.5 mm (G gap type)
40 A max.
24 A max.
160 mA at 5 VDC
15 A max.
D3V-01
Crossbar
Gold alloy
1.0 mm
---
1 mA at 5 VDC
Note:
Minimum applicable loads are indicated by N standard
(JIS C5003). The equation λ60=0.5 x 10-6 / operations
reference values. This
indicates that a failure
value represents the failure rate at a 60% (λ60) reliability level
rate of 1/2,000,000 operations can be expected at a reliability
level of 60%
■ Contact Form
SPDT
NC
SPST-NC
NC
SPST-NO
NO
NO
COM
COM
COM
Miniature Basic Switch D3V
79