English
Language : 

D3V Datasheet, PDF (6/18 Pages) Omron Electronics LLC – Miniature Basic Switch
Specifications
■ Ratings
Type
Rated voltage
D3V-21
D3V-16
D3V-11
D3V-6
D3V-01
250 VAC
8 VDC
30 VDC
125 VDC
250 VDC
250 VAC
8 VDC
30 VDC
125 VDC
250 VDC
250 VAC
8 VDC
30 VDC
125 VDC
250 VDC
250 VAC
8 VDC
30 VDC
125 VDC
250 VDC
125 VAC
8 VDC
30 VDC
Non-inductive load
Resistive load
Lamp load
NC
NO
NC
NO
21 A
3A
21 A
5A
14 A
5A
0.6 A
0.1 A
0.3 A
0.05 A
16 A
2A
16 A
4A
10 A
4A
0.6 A
0.1 A
0.3 A
0.05 A
11 A
1.5 A
11 A
3A
6A
3A
0.6 A
0.1 A
0.3 A
0.05 A
6A
3A
6A
3A
6A
3A
0.4 A
0.1 A
0.3 A
0.05 A
0.1 A
---
0.1 A
---
0.1 A
Inductive load
Inductive load
Motor load
NC
NO
NC
NO
12 A
4A
12 A
7A
12 A
5A
0.6 A
0.1 A
0.3 A
0.05 A
10 A
3A
10 A
6A
10 A
4A
0.6 A
0.1 A
0.3 A
0.05 A
6A
2A
6A
3A
6A
3A
0.6 A
0.1 A
0.3 A
0.05 A
4A
---
4A
4A
---
0.4 A
0.2 A
---
---
---
---
Note: 1. The above current values are the normal current values of models with a contact gap of 1 mm (gap F), which vary with the normal current
values of models with a contact gap of 0.5 mm (gap G).
2. Inductive load has a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times the steady-state current.
4. Motor load has an inrush current of 6 times the steady-state current.
5. The ratings values apply under the following test conditions: Ambient temperature: 20±2°C, Ambient humidity: 65±5%, Operating frequency: 30 operations/min
■ Approved Standards
UL1054 (File No. E41515)
CSA C22.2 No.55 (File No. LR21642)
(Only standard ratings are listed.)
Rated voltage
125 VAC
250 VAC
125 VDC
250 VDC
D3V-21G
D3V-16
3/4 HP 16 A, 1/2 HP
20.1 A, 3/4 HP 16 A, 1/2 HP
---
0.6 A
---
0.3 A
D3V-16G
16 A, 1/2 HP
16 A, 1/2 HP
0.1 A
---
D3V-11
11 A, 1/2 HP
11 A, 1/2 HP
0.6 A
0.3 A
D3V-11G
11 A, 1/2 HP
11 A, 1/2 HP
0.1 A
---
D3V-6
6 A, 1/4 HP
6 A, 1/4 HP
---
---
D3V-6G
6 A, 1/4 HP
6 A, 1/4 HP
---
---
D3V-01
0.1 A
---
---
---
EN 61058-1: 1992+A1: 1993 (License No. 119151L)
Rated voltage
125 VAC
250 VAC
250 VAC
D3V-21G
---
20 (4) A
21 (8) A**
D3V-16
---
16 (3) A
D3V-11
---
11 (3) A
D3V-6
---
6 (2) A
D3V-01
0.1 A
---
Testing conditions: 50,000 operations, T85 (0°C to 85°C) for D3V-21/D3V-01, T105 (0°C to 105°C) for D3V-16/D3V-11/D3V-6 and T200
(0 to 200°C) for D3V-6/-01 with suffix “T”, T155 (0 to 155°C) for D3V-11 with suffix “T”.
**Testing conditions: 10,000 operations, T85 (0°C to 85°C)
EN 60695-2-11 Ed.2, EN 60695-2-12 Ed.2 - - Glow-wire flammability test methods
Rated voltage
125 VAC
250 VAC
D3V-16
---
16 (3) A
D3V-11
---
11 (3) A
D3V-6
---
6 (2) A
D3V-01
0.1 A
---
78
Miniature Basic Switch D3V