English
Language : 

H3CA8DC24 Datasheet, PDF (7/16 Pages) Omron Electronics LLC – DIN-sized (48 x 48, 45 x 75 mm) Timer with Digital Setting and LCD Display
Dimensions
Note: All units are in millimeters unless otherwise indicated.
■ Timers
H3CA-A/-8H
H3CA-FA
H3CA
Panel Cutouts
When mounting
a single unit
t = 1 to 3.2 mm
Horizontally connecting n units
No front cover:
N = (48n − 2.5)+1/−0
With front cover:
N = {48n − 2.5 + (n − 1) x 3}+1/−0
45+−00.6 (N)
(N)
Mounting Holes
Two,M4 or 4.5 dia. holes
Note: When mounting two or more
timers in line, dimension L
between two adjacent timers
should be 10 mm min.
■ Accessories (Order Separately)
Track Mounted Front Connecting Socket
P2CF-11
Eleven, M3.5 × 7.5
sems
Two,
4.5 dia.
holes
P2CF-08
Eight, M3.5 × 7.5
sems
Two,
4.5 dia.
holes
Terminal Arrangement
(Top View)
Mounting Holes
Two, 4.5 dia.
mounting holes
Note: P2CF-11 can be
used as a front
connecting socket.
Terminal Arrangement
(Top View)
Mounting Holes
Two, 4.5 dia. or
Two, M4
Note: P2CF-08 can be
used as a front
connecting socket.
Mounting Height of
Timer with Socket
108.1
Mounting Height of
Timer with Socket
97.2
7