English
Language : 

S82J Datasheet, PDF (6/20 Pages) Omron Electronics LLC – Compact and Economical Switch mode Power Supplies with Capacities Up to 600W
Other
Item
Ambient temperature
Ambient humidity
Dielectric strength
Insulation resistance
Vibration resistance
Shock resistance
Terminal screw
tightening
Output indicator
Electromagnetic
interference
(See note 2.)
EMC
EMC standards
Approved
standards
UL
CSA
VDE
Weight (See note 9.)
100 to 240 VAC input
100 or 200 VAC
(selected automatically)
10 W
25 W
50 W 100 W (24 V) 100 W
150 W
(5, 12, 15 V)
Operating: See the derating curve in the Engineering Data section.
Storage: −25 to 65°C (with no condensation and icing)
Operating: 25% to 85%
Storage: 25% to 90%
3.0 kVAC, 50/60 Hz for 1 min (between all inputs and all outputs)
2.2 kVAC, 50/60 Hz for 1 min (between all inputs and GR terminal)
1.0 kVAC, 50/60 Hz for 1 min (between all outputs and GR terminal)
100 MΩ min. (between all outputs and all inputs/GR terminals at 500 VDC)
10 to 55 Hz, 0.375-mm double amplitude for 2 h each in X, Y, and Z directions
300 m/s2, 3 times each in ±X, ±Y, and ±Z directions
0.74 N·m
1.08 N·m
100 or 200 VAC
(selectable)
300 W
600 W
Yes (green)
Conforms to FCC Class A
Emission Enclosure:
EN55011 class A
Emission AC Mains:
EN55011 class A
Immunity ESD:
EN61000-4-2: 4 kV contact discharge (level 2)
8 kV air discharge (level 3)
Immunity RF-interference:
ENV50140: 10 Vm (80 MHz to 1 GHz) (level 3)
Immunity Conducted Disturbance: ENV50141: 10 V (0.5 to 80 MHz) (level 3)
Immunity Burst:
EN61000-4-4: 2 kV power-line (level 3)
2 kV output line (level 4)
Conforms to EN50081-2 and EN50082-2
Conforms to EN50081-2
and EN50082-2 (See
note 6.)
With noise filter, confirms
to EN50081-1 (See note
6 and 7.)
UL508 (Listing), 1950, Class 2
(per UL1310) (See note 10.)
UL508 (Listing), 1012, 1950 (See note 8.) UL508/1012
CSA C22.2 No. 14, No. 950,
Class 2 (See note 10.)
CSA C22.2 No. 14, No. 950
CSA EB1402C
EN50178 (VDE0160) and EN60950
Terminal types (only terminal part): VDE0106/P100
250 g
max.
350 g
max.
400 g
max.
500 g max. 1,000 g max.
2,000 g 2,500 g max.
max.
Note: 1. DC inputs not included in safety standard approvals.
2. At 100% load for rated input voltage (100 VAC or 200 VAC).
3. The output specification is defined at the power supply output terminals.
4. For resetting, turn OFF the power supply, leave for more than three minutes (90 seconds min. for the 300-W models), and then turn ON
the power supply.
5. For resetting, turn OFF the power supply, leave for more than one minute, and then turn ON the power supply.
6. To ensure the Emission Enclosure rating ferrite ring cores (recommended model: S82Y-JC-T) should be used on all cabling.
7. To ensure the Emission AC Mains rating for EN50081-1 (only for 200-VAC input), a noise filter (recommended models: S82Y-JF3-N for
300-W, S82Y-JF6-N for 600-W) should be used on the input lines.
8. With UL508, 150-W connector type has “Recognized” approval.
9. The weight indicated is the weight of the open-frame type. (Includes the covers for 300-W and 600-W models)
10. Class 2 approved for 10-W, 25-W (except for 5-V output), and 50-W (only for 24-V output) models.
I Reference Value
Item
Reliability (MTBF)
Life expectancy
Value
135,000 hours min.
10 yrs. min.
Definition
MTBF stands for Mean Time Between Failures, which is calculated according to the probabil-
ity of accidental device failures, and indicates reliability of devices. Therefore, it does not nec-
essarily represent a life of the product.
The life expectancy indicates average operating hours under the ambient temperature of
40°C and a load rate of 50%. Normally this is determined by the life expectancy of the built-
in aluminum electrolytic capacitor.
L-84
Switching Power Supply S82J