Ratings
Rated voltage (V)
Non-inductive load (A)
Resistive load
Lamp load
Inductive load (A)
Inductive load
Motor load
125 VAC
250
400
8 VDC
14
30
125
250
NC
10
10
10
10
10
6
0.8
0.4
NO
NC
NO
NC
3
1.5
10
2
1
10
1.5
0.8
3
6
3
10
6
3
10
4
3
6
0.2
0.2
0.8
0.1
0.1
0.4
NO
NC
NO
5
2.5
3
1.5
1.5
0.8
6
6
4
0.2
0.1
Note: 1. The above values are continuous currents.
2. Inductive loads have a power factor of 0.4 or higher (AC) or a time constant of 7 ms or lower (DC).
3. Lamp loads have a inrush current of 10 times the normal current.
4. Motor loads have a inrush current of 6 times the normal current.
Inrush current
30 A max.
Characteristics
Degree of protection *1
IP67 (EN60947-5-1)
Durability *2
Mechanical
Electrical
30,000,000 operations min. (snap-action)
10,000,000 operations min. (slow-action)
500,000 operations min. (10 A resistive load at 250 VAC)
Operating speed
1 mm/s to 0.5 m/s
Operating frequency
Mechanical
Electrical
120 operations/minute
30 operations/minute
Contact resistance
25 mΩ max.
Minimum applicable load *4
General load 180 mA resistive load at 5 VAC
Gold-clad contact 20 mA resistive load at 5 VAC
(N-level reference value)
Rated insulation voltage (Ui)
600 V (EN60947-5-1)
Rated frequency
50/60 Hz
Protection against electric shock
Class I (with ground terminal)
Pollution degree (operating environment)
3 (EN60947-5-1)
Between terminals
of same polarity
2.5 kV (snap-action)/4 kV (slow-action)
Impulse withstand voltage Between terminals
(EN60947-5-1)
of different polarity
4 kV (slow-action)
Between each
terminal and ground
4 kV
Insulation resistance
100 MΩ min. (at 500 VDC) between terminals of the same polarity and between each
terminal and non-current-carrying part
Contact gap
2 × 2 mm min. (slow-action)
2 × 0.5 mm min. (snap-action)
Vibration resistance
Malfunction
10 to 55 Hz, 0.75 mm single amplitude
Shock resistance
Destruction
Malfunction
1,000 m/s2 min.
300 m/s2 min.
Conditional short-circuit current
100 A (EN60947-5-1)
Conventional enclosed thermal current (Ithe)
20 A (EN60947-5-1)
Ambient operating temperature
–40 to 80°C (with no icing) *3
Ambient operating humidity
95% max.
Weight
Approx. 250 g
Note: 1. The above values are initial values.
2. The above values may vary depending on the model. Consult your OMRON sales representative for details.
*1. The degree of protection is tested using the method specified by the standard (EN60947-5-1). Confirm that sealing properties are sufficient for
the operating conditions and environment beforehand.
*2. The durability is for an ambient temperature of 5 to 35°C and ambient humidity of 40% to 70%. For further conditions, consult your OMRON
sales representative.
*3. –20 to 80°C for the flexible-rod type.
*4. The above values may vary depending on switching frequency, environmental condition, and relativity level, consult your OMRON sales
representative.
6