English
Language : 

D4B-1111N Datasheet, PDF (10/16 Pages) Omron Electronics LLC – Snap-action contact with certified direct opening operation certification
D4B-@N
Top Plunger
D4B-@@70N
PT
9.2 dia.
Stainless steel
plunger
OP
16 Four, M3.5 × 19.5
head
mounting screws
20
Top Roller Plunger
D4B-@@71N
12.7 dia. × 4.8
stainless steel roller
PT
OP
9.2 dia.
16
Four, M3.5 × 19.5
head
mounting screws
20
60±0.2
8
5.3
30±0.2
40+10
Two, 5.3-dia.
mounting holes
Two, M4 × 12 cover
mounting screws
Cover
7.3
97
74 77
15 Conduit opening
31.5
43
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
60±0.2
8
5.3
30±0.2
40+10
Two, 5.3-dia.
mounting holes
Two, M4 × 12 cover
mounting screws
Cover
7.3
97
74 77
15 Conduit opening
31.5
43
Operating characteristics
Model
Operating force
Release force
Pretravel
Overtravel
Movement differential
Direct opening travel
Direct opening force
Total travel
OF max.
RF min.
PT max.
PT (2nd) *1 *3
OT min.
MD max. *2
DOT min. *4
DOF min. *4
TT *3
Free position
Operating position
FP max.
OP
D4B-@@70N
18.63 N
1.96 N
2 mm
(3 mm)
5 mm
1 mm
3.2 mm
49.03 N
(7 mm)
38 mm
35±1 mm
D4B-@@71N
18.63 N
1.96 N
2 mm
(3 mm)
5 mm
1 mm
3.2 mm
49.03N
(7 mm)
51 mm
48±1 mm
Note: Variation occurs in the simultaneity of
contact opening/closing operations of
2NC contacts. Check contact
operation.
*1. Only for slow-action models.
*2. Only for snap-action models.
*3. Reference values.
*4. Must be provided to ensure safe
operation.
Coil Spring (Non-directional) *2
D4B-@@81N
Plastic Rod (Non-directional) *2
D4B-@@87N
Stainless steel coil spring
The Switch can be
actuated in any
direction except to
the axis center.
(40) *1
18.2 dia.
203.5±1.2
29.1
60±0.2
8
5.3
30±0.2
40+10
Seal cap
Four, M3.5 × 7
mounting screws
Two, 5.3-dia.
mounting holes
Two, M4 × 12 cover
mounting screws
Cover
7.3
6.6 dia.
15.7 16
2.7
74 77
15
31.5
43
Conduit
opening
Plastic rod
The Switch can be
actuated in any
direction except to
the axis center.
(40) *1
18.2 dia.
203.5±1.2
29.1
60±0.2
8
5.3
30±0.2
40+10
Seal cap
Four, M3.5 × 7
head mounting
screws
Two, 5.3-dia.
mounting holes
Two, M4 × 12 cover
mounting screws
7.3
Cover
6.6 dia.
15.7 16
2.7
74 77
15
31.5
43
Conduit
opening
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
*1. Be sure to adjust the dog to within 40 mm from the top end of the coil spring.
*2. In terms of construction, the Switch is a General-purpose Limit Switch rather than a Safety Limit Switch.
Operating characteristics
Model D4B-@@81N
Operating force
Pretravel
OF max.
PT max.
1.47 N
15°
D4B-@@87N
1.47 N
15°
Note: Variation occurs in the simultaneity of
contact opening/closing operations of
2NC contacts. Check contact
operation.
10