D2D Datasheet, PDF (6/8 Pages) Omron Electronics LLC – Door Interlock Switch
Note: 1. Unless otherwise specified, all units are in millimeters and a tolerance of ±0.4 mm applies to all dimensions
2. The operating characteristics are for operation in the A direction( )
■ Pull-on Lock Models
Screw Mounting
22±0.1
D2D-2000
16
8 dia.
A
TTP OP
(see
note)
(see
note)
FP
OP TTP
Note: At pull-on lock operation.
Panel Mounting
D2D-2100
TTP OP
(see (see
note) note)
FP
OP
TTP
10.4
25.2
30
40±0.1
8 dia.
A
10.4
25.2
Note: At pull-on lock operation.
30
4.3±0.05 dia.
1.8
5.8
33.6
Momentary Operation
(Normal Operation)
13
OF max.
TTF max.
23.6
OT min.
FP max.
OP
TTP max.
6.35±0.1
1.65
+0.1
0
dia.
Model D2D-2000 D2D-2100
NC-OFF
NO-ON
200 gf
300 gf
600 gf
4.5 mm
14.3 mm
10.3 mm
NC-OFF 13.5 ± 0.6 mm 9.5 ± 0.6 mm
NO-ON 12.7 ± 0.6 mm 8.7 ± 0.6 mm
8.3 mm
4.3 mm
12.4
Four quick-connect
terminals (#250)
21.2
2.0
21.8
31.7
6.35±0.1
12.4
Four quick-connect
terminals (#250)
1.65
+0.1
0
dia.
Pull-on Lock Operation
Model D2D-2000 D2D-2100
OF max.
2,000 gf
PT max.
2 mm
OT min.
0.4 mm
MD max.
1.5 mm
FP max.
14.3 mm
10.3 mm
OP
15.1 ± 0.6 mm 11.1 ± 0.6 mm
TTP max. 16.5 mm
12.5 mm
Precautions
Be sure to read the precautions and information common to all Snap Action and Detection Switches, contained in the Technical User’s Guide,
“Snap Action Switches, Technical Information” for correct use.
■ Correct Use
Actuation
Using Microloads
Apply operation force to the pin plunger in the direction it operates.
Applying forces laterally or from an oblique direction may damage the
pin plunger.
Using a model for ordinary loads to switch microloads may result in
faulty operation. Instead, use the models that are designed for
microloads and that operate in the following range;
Incorrect Correct Incorrect
30
26mA
24
Inoperable
range
Operating
range
12
5
160mA
0
0.1
1
10
100
1,000
Current (mA)
However, even when using microload models within the operating
range shown above, if inrush current or inductive voltage spikes
occur when the contact is opened or closed, then contact wear may
increase and so decrease the service life. Therefore, insert a contact
protection circuit where necessary.
30