English
Language : 

D2D Datasheet, PDF (2/8 Pages) Omron Electronics LLC – Door Interlock Switch
Specifications
■ Characteristics
Item
D2D-1000 models
D2D-2000 models
D2D-3000 models
Operating speed
10 mm/s to 1 m/s
Operating frequency
Mechanical: 300 operations per minute max.
Electrical: 30 operations per minute max.
Contact resistance
50 mΩ max.
Insulation resistance
100 MΩ min. (at 500 VDC)
Dielectric strength
50/60 Hz, 1mm
(See note 2)
Between terminals 2,000 VAC
of same polarity
Between terminals 2,000 VAC
and ground
1,000 VAC
1,500 VAC
2,000 VAC
2,000 VAC
Between terminals 2,500 VAC
1,500 VAC
---
and non-current
carrying metal parts
Between terminals 4,000 VAC
---
and actuator
4,000 VAC
Vibration resistance
Malfunction: 10 to 55 Hz, 1.5 mm double amplitude
Shock resistance
Destruction
1,000 m/s2 (approx 100G) max.
Malfunction
500 m/s2 (approx. 50G) max. 300 m/s2 (approx. 30G) max. 500 m/s2 (approx. 50G) max.
Degree of protection
IEC IP40
Degree of protection vs. electric shock
Class II
Proof tracking index (PTI)
175
Ambient operating temperature
-25° to 85°C (at 60% RH max.) with no icing
Ambient operating humidity
85% max (for 5°C to 35°C)
Life expectancy
Mechanical: 10,000,000 operations min. at 60 operations/minute
Electrical: 100,000 operations min. at 30 operations/minute
Weight
Approx. 14 g (D2D-1000)
Note: 1. Data shown are of initial value
2. The dielectric strength shown is measured using a separator between the switch and metal mounting plate
■ Ratings (Reference values)
Type
Standard
Pull-on lock
125 VAC
250 VAC
125 VAC
250 VAC
Voltage
Resistive load
NC
NO
16 A
10 A
Motor load
NC
NO
4A
---
Note: 1. The above values ar for steady-state current and the motor load has an inrush current of 6 times the steady-state current.
2. The ratings apply under the following test conditions: Ambient Temperature = 20±2°C, Ambient Humidity = 65±5%, Operating frequency = 30 operations/min.
■ Approved Standards
UL Recognized (File No. E41515)(
CSA Certified (File No. LR21642)
Rated voltage
125 VAC
250 VAC
D2D-1000
---
16 A
D2D-2000
---
10 A
D2D-3000
3/4 hp
16A, 1.5 hp
EN61058-1 (File No. 136005 VDE approval)
Rated voltage
250 VAC
D2D-1000
16(4) A
D2D-2000
10 A
D2D-3000
16(4) A
Testing conditions: 1E4 (10,000 operations), T85 (0°C to 85°C)
Note: The value in parentheses indicate motor load ratings.
EN61058-1 (File No. R9551934, TÜV Rheinland approval)
■ Contact Specifications
Item
Specification
Material
Gap (standard value)
Inrush current
Minimum applicable load
(see note)
Standard
model
Pull-on lock
model
Rivet
Silver
3 mm min.
1 mm
30 A max.
24 A max.
160 mA at 5 VDC
Note: Minimum applicable loads are indicated by N standard refer-
ence values. This value represents the failure rate at a 60%
(Tλh6e0)erqeuliaatbioilnityλ6le0v=e0l.(5JxIS1C0-560/0o3p)e. rations indicates that a failure
rate of 1/2,000,000 operations can be expected at a reliability
level of 60%
Rated voltage
24 VDC
D2D-3104
4A
Testing conditions: 5E4 (50,000 operations), T85 (0°C to 85°C)
26
Door Interlock Switch D2D