English
Language : 

D2D Datasheet, PDF (3/8 Pages) Omron Electronics LLC – Door Interlock Switch
Engineering Data
■ Mechanical Service Life
100,000
70,000
50,000
30,000
Ambient temperature: 20±2 °C
Ambient humidity: 65±5%
Without load
Operating frequency: 300 operations/min
10,000
7,000
5,000
3,000
1,000
0 10 20 30 40 50 60 70 80 90 100
OT (%)
■ Contact Form
SPDB-NO/NC
SPDB-NO
SPDB-NC
D2D-1000 D2D-2000
D2D-1100 D2D-2100
SPDB-NO +
SPDB-NO/NC
D2D-1001
D2D-1101
DPDB-NO
D2D-1002
D2D-1102
■ Electrical Service Life
10,000
7,000
5,000
3,000
Operating frequency:
30 operations/min
p.f. = 1
AC250V
1,000
700
500
300
100
0
1
2
3
4
5
6
Rated operating current (A)
■ Mounting Holes
Screw mount switches may be panel mounted using M4 mounting
screws with plane washers or spring washers to securely mount the
switch. Tighten the screws to a torque of 0.49 to 0.69 N·m
Panel Mount Holes
Panel Cutout Dimensions
Two, 4.3-dia. mounting
holes or M4 screw holes
13.5 ± 0.1
2.2 ± 0.1
Panel
Note
1.3 R max.
Panel thickness: 1.0 to 2.5 mm
Note: Dimension is 36.7±0.1 with a panel
thickness of 1.0 mm and 37.0±0.1 with
a panel thickness of 2.5 mm
D2D-3103
D2D-3104
Screw mount type
panel
Panel mount type
panel
Snap-fit panel mount switches use the panel cutout hole illustrated
above. When mounting on a metal surface, be sure to provide a sep-
arator between the switch and mounting plate.
■ Pull-on Lock Function
When opening or closing the door, the power ON state of the switch can be checked with the door left open. By closing the door after maintenance
inspection, the switch will resume the normal momentary action. (this feature is ideal for conducting the electrical continuity test, inspection, repair,
etc. of the switch after its assembly.)
Example
State
To turn ON the power when the To turn OFF the power when the To turn ON the power with the door
door is closed
door is open
left open
Pull
Connection NO-NO
NC-NC
ON
OFF
OFF
ON
ON
OFF
Door Interlock Switch D2D
27