E32-D22B Datasheet, PDF (46/67 Pages) Omron Electronics LLC – These Fibers Units can be used in a variety of applications, such as detecting the presence of workpieces and positioning.
Through-beam Fiber Units Through-beam models consist of two parts: an emitter and a receiver.
Environment-resistant Models Heat-resistant Models
E32-T51 R35
Sensing surface
1.5 dia.
M4×0.7 (brass/nickel plating)
Width 7, thickness 2.4 (nickel-plated brass)
Washer (nickel-plated iron)
2.2 dia.
2.85 dia.
1
15
17
2,000
Note: The maximum allowable temperature is 150°C. The maximum al-
lowable temperature for continuous operation is 130°C.
E32-T81R-S R10
Sensing surface
0.7 dia.
M2.6×0.45
M4×0.7 (SUS303)
Width 7,
thickness 2.4 (SUS304)
Washer (SUS)
Protective tube
Fluororesin tube 2 dia.
Flexible Break-resistant Fluororesin coating R@ Standard
Cutting free (Cutter provided)
E32-T54 R35
Sensing surface
2.45
3 dia. (SUS303)
2.2 dia.
2 dia.
25
20
45
2,000
Note: The maximum allowable temperature is 150°C. The maximum
allowable temperature for continuous operation is 130°C.
4 dia. 2.2 dia.
3
20
E32-T84S-S R25
4 dia.
(75)
10
A
A
14.2
12
2,000
2,000
25(B)
30
*
*
30(B)
E32-T61-S R25
Sensing surface
1 dia.
M2.6×0.45
Note: The maximum allowable temperatures for sec-
tions A and B are 200°C and 110°C, respective-
ly. The section inserted into the Amplifier Unit
(indicated by *), however, must stay within the
Amplifier Unit's operating temperature range.
M4×0.7 (SUS303)
Width 7, thickness 2.4 (SUS304)
Washer (SUS)
2.8 dia. flexible tubes
(SUS304)
4 dia.
2.2 dia.
30 max. 6
12
R5 3 dia.
90°
3.5 dia.
3 dia. (SUS303)
Sensing surface
Lens (2 dia.)
4 dia.
4 dia.
Flexible tube:
2.9 dia.
(stainless steel)
2.2 dia.
Note: The maximum allowable temperatures
for sections A and B are 200°C and
110°C, respectively. The section in-
serted into the Amplifier Unit (indicated
by *), however, must stay within the
Amplifier Unit's operating temperature
range.
3
20
4 dia.
*2
10
A
2,000
*1
30
25(B)
*2 The diameter is 6 mm if the fiberlength exceeds 10 m.
Note: The maximum allowable temperatures for sections A and B are 200°C
and 110°C, respectively. The section inserted into the Amplifier Unit (in-
dicated by *1), however, must stay within the Amplifier Unit's operating
temperature range.
Environment-resistant Models Chemical-resistant Models
E32-T11F R4
lens diameter: 3.7 mm 7.2 dia. (PFA) nut (PFA)
2.2 dia. (Fluororesin)
10
(10.7)
R3.6
19.8
10
3
35
2,000
E32-T12F R40
Sensing surface
Lens 4 dia.
5 dia. (Fluororesin)
20
2,000
E32-T14F R40
5 dia. (Fluororesin)
4 dia.
2.2 dia.
E32-T51F R40
Sensing surface
lens diameter:
3.7 dia.
5 dia. (Fluororesin)
4 dia.
2.2 dia.
100
2.2 dia.
4.5
21
E32-T81F-S R10
6 dia.
(R6)
2,000
PFA cover
Sensing surface:
3.7 dia
(0.8)
30
20
2,000
100
100
Protective tube 2 dia. (PFA tube)
(70)
A
2,000
4 dia.
2.2 dia.
*
30(B)
Note: The maximum allowable temperatures for sec-
tions A and B are 200°C and 110°C, respective-
ly. The section inserted into the Amplifier Unit
(indicated by *), however, must stay within the
Amplifier Unit's operating temperature range.