E32-D22B Datasheet, PDF (14/67 Pages) Omron Electronics LLC – These Fibers Units can be used in a variety of applications, such as detecting the presence of workpieces and positioning.
Features/Applications
Environment-resistant Models
Heat-resistant
• These Fiber Units can be used for various applica-
tions in temperatures up to 400°C.
■ Applications
Detecting wafers in
high-temperature en-
vironments
E32-T84S-S
E32-T61-S
■ Ratings/Characteristics
150°C models
200°C and higher models
E32-T81R
E32-D81R
All other models
Min. bending
radius
Fiber material
35 mm
10 mm
Plastic
Glass (fluo-
(fluororesin coating) roresin coating)
25 mm
Glass (SUS spi-
ral coating)
■ Overview of Model Variations
Type Ambient tem-
perature range
Features
−40°C to 150°C M4 screw
Shape, sensing distance (mm)*1 Model number
760
E32-T51
−40°C to 200°C L-shaped, long distance
1,300
E32-T84S-S
−60°C to 350°C M4 screw
450
E32-T61-S
−60°C to 350°C M6 screw
−40°C to 400°C M6 screw, with sleeve
90
E32-D61-S
60
E32-D73-S
*1 The sensing distances apply for use in combination with the E3X-DA-S Amplifier Unit (general-purpose, standard mode).
*2 Order the Fiber Unit based on the Amplifier Unit. Use the E32-D@-S if the E3X-DA@-S, E3X-MDA@, or E3X-DAC@-S is used.
Use the E32-D@ if any other Amplifier is used.
Chemical-resistant
• Built-in lens and high-power beam reduce the influ-
ence of dirt and drops of water.
• Round design prevents drops of water sticking to the
head (E32-T11F).
■ Applications
Detecting workpieces in cleaning processes
E32-T14F
■ Overview of Model Variations
Type
Features
Water-resistant round head
Built-in lens, high power
Heat-resistant up to 200°C
E32-T12F
■ Ratings/Characteristics
All other models E32-T51F
Ambient tem-
perature range
−40°C to 70°C
−40°C to
150°C
Fiber material
Plastic
(fluororesin coating)
E32-T81F-S
−40°C to 200°C
Glass (fluororesin
coating)
Shape, sensing distance (mm)*
Model number
2,000
E32-T11F
3,000
E32-T12F
700
E32-T81F-S
Built-in lens, high power
95
E32-D12F
*The sensing distances apply for use in combination with the E3X-DA-S Amplifier Unit (general-purpose, standard mode).