■ Approved by Standards
UL (File No. E41515)
Model
G2AK-@
Coil ratings
6 to 100 VAC
6 to 50 VDC
Engineering Data
Maximum Switching Power
DC resistive load
AC resistive load
AC inductive load
(cosφ = 0.4)
DC inductive load
L/R = 7 ms
Contact ratings
1 A 120 VAC (resistive load)
1 A 30 VDC (inductive load)
Endurance
10,000
5,000
1,000
500
24-VDC resistive load
24-VAC in-
ductive load
L/R = 7 ms
100
110-VAC
50
resistive
load
110-VAC in-
ductive load
10 (cosφ = 0.4)
G2AK
Switching voltage (V)
Malfunctioning Shock
Not energized
Energized
Switching current (A)
Shock direction
Unit: m/s2
Number of samples = 5
Measurement conditions: Impose a shock of
100 m/s2 in the ±X, ±Y, and ±Z directions three
times each with the Relay energized and not
energized to check the shock values that cause
the Relay to malfunction.
Changes in Operating Characteristics vs.
External Magnetic Field
G2AK-232A 24 VDC (Mean Value)
(Mean Value)
Condition: Changes in set and reset voltages are
checked in the worst direction in an external even
magnetic field.
Set voltage
Reset voltage
Condition: Changes in set and reset voltages are
checked in the worst direction in an external even
magnetic field.
Set voltage
Reset voltage
Hold Force Attenuation vs.
Elapsed Time
G2AK-232A 24 VDC
Conditions: The rate of hold force
attenuation is checked with the Relays at
room temperature (20°C to 30°C) and high
temperature (80°±2°C) with the rated
voltage imposed.
Room temperature (max.)
Room temperature (min.)
High temperature (max.)
High temperature (min.)
Even magnetic field strength (Oe)
Even magnetic field strength (Oe)
Elapsed time (h)