English
Language : 

G2AK-232A-DC24 Datasheet, PDF (2/8 Pages) Omron Electronics LLC – Magnetic Latching Version of G2A Ideal for Sequence Control
■ Accessories (Order Separately)
G2AK
Sockets
Item
Without Hold-down
Clip
With Hold-down Clip
DIN Track-mounting
Socket
Screw terminals
PYF14A(-E)
PYF14A-TU
PYF14T
---
Solder terminals
PY14
PY14-3
PY14-Y2
Back-connecting Relay
Wire-wrap terminals
PY14QN(2)
PY14-0
PY14QN-Y2
---
PCB terminals
PY14-02
---
Note: See the G2A Datasheet for detailed information on the Relay Hold-down Clips and Socket Mounting Plates.
Specifications
■ Coil Ratings
Rated
voltage
6 VAC
12 VAC
24 VAC
50 VAC
100 VAC
6 VDC
12 VDC
24 VDC
48 VDC
Set coil
Rated current
50 Hz 60 Hz
Coil
resistance
308 mA 300 mA 6.5 Ω
162 mA 158 mA 28 Ω
66 mA 64 mA 145 Ω
34 mA 33 mA 590 Ω
19 mA 18.5 mA 2,150 Ω
360 mA
14 Ω
170 mA
65 Ω
85 mA
270 Ω
44 mA
1,050 Ω
Reset coil
Rated current
50 Hz 60 Hz
Coil
resistance
72 mA 70 mA 32 Ω
40 mA 39 mA 125 Ω
22.6 mA 22 mA 460 Ω
11.3 mA 11 mA 1,900 Ω
12.3 mA 12 mA 3,600 Ω
160 mA
32 Ω
85 mA
125 Ω
50 mA
460 Ω
24 mA
1,900 Ω
Set
Reset Max. Power consumption
voltage voltage voltage Set coil Reset coil
80%
max. of
rated
voltage
80%
max. of
rated
voltage
110% of Approx. 1.6 Approx. 0.5
rated to 2.0 VA to 1.2 VA
voltage
Approx. 2.0 Approx. 1.0
to 2.2 W to 1.2 W
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%, –20% for AC rated current
and ±15% for DC coil resistance.
2. The AC coil resistance values are for reference only.
3. Performance characteristics data are measured at a coil temperature of 23°C.
4. The rated current of the AC operating coil is half-wave rectified current and is measured with a DC ammeter.
5. The peak reverse-breakdown voltage of the built-in diode is 1,000V.
6. The set coil of the Relay rated at 6 VDC is of the 5-minute rating. However, when it is used by connecting a diode is series, it can be of
the continuous rating.
7. By connecting an external resistor to each of the set and reset coils as shown in the table below, the rated current of the Relay can be
increased.
8. The maximum voltage is one that is applicable instantaneously to the Relay coil at 23°C and not continuously.
Rated voltage
110 VAC
200 VAC
220 VAC
100 VDC
Connected coil
voltage
100 VAC
100 VAC
100 VAC
48 VDC
External resistor
Set coil
Reset coil
Resistance
Capacity
Resistance
Capacity
0.27 kΩ
0.5 W min.
0.39 kΩ
1/4 W min.
2.7 kΩ
5 W min.
8.2 kΩ
3 W min.
3.3 kΩ
6 W min.
9.1 kΩ
3 W min.
1.1 kΩ
10 W min.
2.0 kΩ
6 W min.
Note: Use a resistor having the above resistance value with tolerances of ±10% for external connection.