DRT2-TS04P Datasheet, PDF (4/28 Pages) Omron Electronics LLC – Remote I/O Terminals with Transistors
Wide variety of control and maintenance functions using DeviceNet.
Monitor network devices using
a DeviceNet Configurator.
PLC
DeviceNet Configurator
Settings and monitoring
for startup
Settings and monitoring
for maintenance
CS/CJ-series
DeviceNet Unit
Board Terminals
with MIL Connectors
DRT2-ID32B(-1)
DRT2-OD32B(-1)
DRT2-MD32B(-1)
DRT2-ID32BV(-1)
DRT2-OD32BV(-1)
DRT2-MD32BV(-1)
First Board-type Smart Slave Terminals
User boards attach easily to
the DRT2- D32V(-1) using screws.
I/O Control and Maintenance
Remote I/O Terminals with
Screw-less Clamps
Remote I/O Terminals
with Transistors
DRT2-ID32SL(H)(-1)
DRT2-OD32SL(H)(-1)
DRT2-MD32SL(H)(-1)
Wiring is completed in a single
action.
No screw tightening required.
Removable terminal blocks.
Advanced models detect ground
faults and broken lines in I/O wiring.
Applicable wire sizes range
from AWG24 to AWG16 (0.2
to 1.25 mm2 dia.)
DRT2-ID16(-1)
DRT2-OD16(-1)
DRT2-ID08(-1)
DRT2-OD08(-1)
DRT2-MD16(-1)
I/O points can be
extended by adding
Expansion Units.
Single action
Remote I/O Terminal
with Relay Outputs
DRT2-ROS16
One-step relay exchange
Operation time monitor
function enabled by
combining Remote I/O
Terminals with
Expansion I/O Units.
Environment-resistive
Terminals with Transistors
(with detection functions)
DRT2-ID08C(-1)
DRT2-OD08C(-1)
DRT2-HD16C(-1)
High resistance to
environments (IP67).
Detecting shorts in the
sensor power supply is
also possible.
Environment-resistive
Terminals with Transistors
(without detection functions)
DRT2-ID04CL(-1)
DRT2-OD04CL(-1)
DRT2-ID08CL(-1)
DRT2-OD08CL(-1)
DRT2-MD16CL(-1)
DRT2-HD16CL(-1)
DRT2-WD16CL(-1)
Remote I/O Terminals
with 3-tier Terminal Blocks
DRT2-ID16TA(-1)
DRT2-OD16TA(-1)
DRT2-MD16TA(-1)
The 3-tier Terminal Block
means that wiring
locations are easy to find
with no wiring to
intermediate terminals.
MIL Connector
Terminals
DRT2-ID32ML(-1)
DRT2-OD32ML(-1)
DRT2-MD32ML(-1)
DRT2-ID16ML(-1)
DRT2-OD16ML(-1)
DRT2-ID16MLX(-1)
DRT2-OD16MLX(-1)
Ultra-small 32-point remote
terminals (35 x 60 x 80 mm
(W x D x H)).
Models with 8 Input,
8 Output, or 16 I/O Points
Added to the Lineup
Remote I/O Terminals with
IP67 High Environmental
Resistance
Terminals with
16 Inputs or Outputs
Remote I/O Terminals
with Transistors
DRT2-ID08(-1)/OD08(-1)/
MD16(-1)
Collect a variety of data from
maintenance systems without
influencing control systems and
productivity.
Communications power supply
voltage monitor, deterioration due
to aging, operating time data, and
other information can be easily
collected and managed via the
network.
Locations of problems can be easily
identified.
Environment-resistive Terminals
with Transistors
DRT2-ID04CL(-1)/OD04CL(-1)/
ID08CL(-1)/OD08CL(-1)/MD16CL(-1)/
HD16CL(-1)/WD16CL(-1)
Smart Slave functions provide robust
support for effective maintenance and
monitoring device operation status.
The terminals conform to IP67 and use
materials selected for resistance to oil
and spattering.
Models with two-output connector are
also available to improve ease of
connection with hydraulic valve
devices.
MIL Connector Terminals
with Transistors
DRT2-ID16ML(-1)/
OD16ML(-1)/
ID16MLX(-1)/
OD16MLX(-1)
Connection with an array of
I/O interfaces is achieved by
combining adaptor boards
for D-Sub or other
interfaces.
4
e-CON Connector Terminals
DRT2-ID16S(-1)
DRT2-MD16S(-1)
Includes industry-standard
e-CON connector that can be
used to connect prewired
sensors without using special
tools.
(The OMRON XN2 Connector can
be used.)
Sensor Input and Maintenance
Analog I/O Terminals
DRT2-AD04/DRT2-AD04H
DRT2-DA02
The DRT2-AD04H offers high
resolution at 1/30,000 (full scale) and
insulation between input channels.
The DRT2-AD04 and DRT2-DA02
support a wide variety of data
sampling function, including scaling,
peak/bottom hold, top/valley hold,
comparator, integral, and differential
operation functions.
Temperature Input
Terminals
DRT2-TS04T
DRT2-TS04P
Offers basically the same functions as
Analog Input Terminals, such as
scaling and comparators.
Also provides functions that are
available only from Temperature
Input Terminals, such as the time in a
preset temperature range and
temperature difference detection
between input channels.
Analog Control and Maintenance
DeviceNet Communications
Unit for E5ZN Digital
Temperature Controllers
E5ZN-DRT
Monitoring and setting of
Temperature Controller from
PLC.
Batch download of all
Temperature Controller
parameters from Configurator.
5
DeviceNet Communications
Units/Cards for Inverters
3G3MV-PDRT2 (for 3G3MV Series)
3G3RV-PDRT2 (for 3G3RV Series)
Frequencies and other
specifications can be designated
from PLC.
Monitor-related maintenance
possible, including output current
(torque) error detection/trace,
operation monitor, and general-
purpose I/O read.
Monitor Control and Maintenance
6