CS1W-MCH71 Datasheet, PDF (3/11 Pages) Omron Electronics LLC – Improve Equipment Design Efficiency and Shorten Tact Time
Specifications
CJ1W-MCH71
General Specifications
Item
Specifications
Model
CJ1W-MCH71
Power supply voltage
5 VDC (from Backplane)
24 VDC (from external power supply)
Voltage fluctuation tolerance
4.5 to 5.5 VDC (from Backplane)
21.6 to 26.4 VDC (from external power supply)
Internal current consumption
5 VDC 0.6 A max.
Weight (Connectors excluded)
210 g max.
Safety standards
UL, CSA, C-TICK, and EC Directives.
Dimensions (mm)
90 (H) × 79.8 (W) × 65 (D) (single)
Altitude
At 2,000 m elevation or lower.
Specifications other than those shown above conform to the general specifications for the CJ series.
Functions and Performance Specifications
Applicable PLC
Type of Unit
Mounting
Number of Units
Method for data
transfer with CPU
Unit
Item
CIO Area for CPU Bus
Unit
DM Area for CPU Bus
Unit
Controlled Devices
Custom Bit Area
Custom Data Area
Custom Data Area
Built-in program language
Control
Control method
Number of controlled
axes
Operating modes
Automatic/Manual Mode
Control unit
Minimum setting unit
Units
Maximum position command value
Control operations
based on com-
mands from the
CPU Unit
Servo lock/unlock
Jogging
STEP operation
Origin search
Forced origin
Absolute origin setting
Error counter reset
Present position preset
Machine lock
Single block
Auto/manual change
Specifications
CJ-series PLCs with CPU Units with unit version 2.0 or later
CPU Bus Unit
CPU unit or expansion rack
One CJ1W-MCH71 Motion Control Unit requires the space of three standard Unit.
Occupies the area for 1 unit (25 words)
For units and tasks: 11 to 25 words (Depending on the number of motion tasks)
Occupies the area for 1 unit (100 words)
For units and tasks: 32 to 74 words (Depending on the number of motion tasks)
For axes: 0-64 words (Depending on the greatest number of the axis used)
For axes: 0-128 words (Depending on the greatest number of the axis used)
For General I/O: 0-1280 words (Depending on setting)
MECHATROLINK-II below supported
• W-series Servo Driver with built-in communications functions
• W-series Servo Driver (OMRON) + Communications I/F Unit (YASKAWA)
• Various I/O units (YASKAWA)
• SMARTSTEP Junior Servo Drive
Up to 30 nodes
* When MECHATROLINK-II devices are connected up to 16 nodes (within 30 m) or 15 nodes (within 50m), a
repeater unit is not required. A repeater unit is required to connect MECHATROLINK-II devices more than the
cases described above.
Dedicated motion control language
MECHATROLINK-II
• Position commands, Speed commands, Torque commands
32 axes max.
Physical axes/Virtual axes: 30 axes max. (Either can be selected for each axis)
Dedicated for virtual axes: 2 axes
RUN mode, CPU mode, Tool mode/System (Depending on the tool)
Automatic mode: Executing built-in programs of MC Unit controls motion.
Manual mode: Executing commands from CPU Unit (PC interface area) controls motion.
Note: The Automatic or Manual Mode is set according to the PC Interface area of the CPU Unit.
1, 0.1, 0.01, 0.001, 0.0001
mm, inch, deg, pulse
-2147483647 to 2147483647 pulses (signed 32-bit)
Mode for unlimited axes feeding is possible.
Example: With 16-bit encoder (65536 pulse/rev), Minimum setting unit: 0.001 mm, 10 mm/rev, the position
command value range will be from -327679999 to 327679999 command units.
Executes Servo driver lock or unlock
Executes continuous feeding independently for each axis, by means of speed set in system parameter x over-
ride.
Feeds a specified distance for a specified axis.
Defines the machines origin according to the search method set in the system parameters.
Forcibly sets the present position to 0 to establish it as the origin.
Sets the origin when an absolute encoder is used.
Offset value: Signed 32-bit (pulses)
Forcibly resets the error counter to 0.
Sets the present position to a user-specified value.
Prohibits the output of motion commands to the axes.
Executes the motion program one block at a time.
Switches between auto mode and manual mode.
3