English
Language : 

S8JX-G03524CD Datasheet, PDF (26/28 Pages) Omron Electronics LLC – Wide Variety of Output Voltage Variations: 48 V for 15 to 150 W, and 5 or 12 V for 150 W
S8JX
In Case There Is No Output Voltage
The possible cause for no output voltage may be that the overcurrent
or overvoltage protection has operated. The internal protection may
operate if a large amount of surge voltage such as a lightening surge
occurs while turning ON the Power Supply.
In case there is no output voltage, please check the following points
before contacting us:
• Checking overcurrent protected status:
Check whether the load is in overcurrent status or is short-
circuited. Remove wires to load when checking.
• Checking overvoltage or internal protection:
Turn the power supply OFF once, and leave it OFF for at least
7 minutes. Then turn it ON again to see if this clears the condition.
Switching the AC Input Voltage between 100 and 200 VAC
150-W, 5-V Models
The input voltage can be switched between 100 V and 200 V by using
the input voltage switch. Make the setting shown in the following
figure for the voltage that will be used. (The input voltage is factory-
set to 200 V.)
Fan Replacement
600-W Model
The service life of the fan is approximately 50,000 hours (at 25°C).
The service life varies, however, depending on the ambient
temperature or other surrounding environmental conditions such as
dust. As a preventive maintenance measure, replace the fan within
approx. two years if it is used at an ambient temperature of 40°C.
Fans (S82Y-JXFAN) are available as replacements.
Fan Set:
Fan (above), instruction sheet, and packing case
Replace the fan as shown in the following illustration.
"115V": 100 to 120 VAC
The input voltage switch is at the back
on the bottom of the Power Supply. "230V": 200 to 240 VAC
300-/600-W Models
The input voltage can be switched between 100 and 200 V by shorting
or opening the input voltage selection terminals. Set the required
voltage as shown below. (The voltage is factory-set to 200 V.)
100-V input
L
N
200-V input
L
N
VOLTAGE SELECT
SHORT 100-120V
OPEN 200-230V
SHORT BAR
VOLTAGE SELECT
SHORT 100-120V
OPEN 200-230V
SHORT BAR
Short with the short bar.
Remove the short bar
and leave the terminals open.
Note: A 300-W model is shown above.
26
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
In the interest of product improvement, specifications are subject to change without notice.