English
Language : 

G3PC_07 Datasheet, PDF (2/6 Pages) Omron Electronics LLC – SSR with Failure Detection Function
I Characteristics
Operate time
Release time
Main circuit
Output ON voltage drop
OFF leakage current
Alarm output
Output ON voltage drop
OFF leakage current
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Ambient temperature
Ambient operating humidity
Weight
Approved standards
EMC
1/2 of load power source cycle + 1 ms max.
1/2 of load power source cycle + 1 ms max.
1.6 V rms max.
10 mA max. (at 200 VAC)
1.5 V max.
0.1 mA max.
100 MΩ min. (at 500 VDC)
2,500 VAC, 50/60 Hz for 1 min
Destruction: 10 to 55 to10 Hz, 0.35-mm single amplitude
Destruction: 294 m/s2
Operating: -20 to 60°C (with no icing or condensation)
Storage: -30 to 70°C (with no icing or condensation)
45% to 85%
Approx. 300 g
UL508, CSA22.2 No. 14, EN60947-4-3 (IEC947-4-3) approved by VDE
Emission
Immunity ESD
Immunity Electromagnetic
Immunity EFT
Immunity Surge transient
Immunity RF disturbance
Immunity Dips
EN55011 Group 1 Class B
IEC947-4-3, EN61000-4-2
4 kV contact discharge
8 kV air discharge
IEC947-4-3, EN61000-4-3
10 V/m (80 MHz to 1 GHz)
IEC947-4-3, EN61000-4-4
2 kV AC power-signal line
IEC947-4-3, EN61000-4-5
2 kV
IEC947-4-3, EN61000-4-6
10 V (0.15 to 80 MHz)
IEC947-4-3, EN61000-4-11
Engineering Data
Input Voltage vs. Input
Current
Input Voltage vs. Input
Impedance
Load Current vs.
Ambient Temperature
10
Ta = +25°C
25
8
20
Input impedance
6
15
Inrush Current Resistivity
(Non-repetitive Input)
The figure will be less than 1/2 for repetitive
input.
250
200
150
4
10
100
Input current
2
5
50
0
0
0
10
20
30
40
-20
0
20
40
60
80 100
10 30 50 100 300 500 1,000 3,000 5,000
Input voltage (V)
Ambient temperature (˚C)
Energized time (ms)
J-72
SSR with Failure Detection Function G3PC