English
Language : 

G3NA-6 Datasheet, PDF (2/14 Pages) Omron Electronics LLC – Solid State Relays (600 VAC Models)
Specifications
■ Ratings
Input (at an Ambient Temperature of 25°C)
Model
G3NA-6@@B
Rated voltage Operating voltage
Impedance
(See note 1.)
5 to 24 VDC
4 to 32 VDC
100 to 240 VAC 75 to 264 VAC
7 mA max.
72 kΩ±20%
Voltage level
Must operate voltage
Must release voltage
4 VDC max.
1 VDC min.
75 VAC max.
20 VAC min.
Note: 1. The input impedance is measured at the maximum value of the rated supply voltage (for example, with the model rated at 100 to 240 VAC,
the input impedance is measured at 240 VAC).
2. Refer to Temperature Characteristics (for Must Operate Voltage and Must Release Voltage) in Engineering Data for further details.
Output
Model
G3NA-610B
G3NA-625B
G3NA-650B
Rated load voltage
400 to 600 VAC
Load voltage range
360 to 660 VAC
Applicable load
Load current (See note 1.)
With heat sink
(See note 2.)
Without heat sink
0.5 to 10 A (at 40°C) 0.5 to 4 A (at 40°C)
0.5 to 25 A (at 40°C) 0.5 to 4 A (at 40°C)
0.5 to 50 A (at 40°C) 0.5 to 6 A (at 40°C)
Inrush current
150 A (60 Hz, 1 cycle)
220 A (60 Hz, 1 cycle)
440 A (60 Hz, 1 cycle)
Note: 1. The load current varies depending on the ambient temperature. Refer to Load Current vs. Ambient Temperature under Engineering Data.
2. When an OMRON Heat Sink (refer to Options) or a heat sink of the specified size is used.
■ Characteristics
Item
Operate time
Release time
Output ON voltage drop
Leakage current
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Weight
G3NA-610B-UTU
G3NA-625B-UTU
G3NA-650B-UTU
1/2 of load power source cycle + 1 ms max. (DC input)
3/2 of load power source cycle + 1 ms max. (AC input)
1/2 of load power source cycle + 1 ms max. (DC input)
3/2 of load power source cycle + 1 ms max. (AC input)
1.8 V (RMS) max.
10 mA max. (at 400 VAC)
20 mA max. (at 600 VAC)
100 MΩ min. (at 500 VDC)
4,000 VAC, 50/60 Hz for 1 min
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Destruction: 1,000 m/s2
Operating:−30°C to 80°C (with no icing or condensation)
Storage: −30°C to 100°C (with no icing or condensation)
Operating: 45% to 85%
Approx. 120 g
468