English
Language : 

D2VW Datasheet, PDF (2/8 Pages) Omron Electronics LLC – Sealed Snap Action Switch
Specifications
■ Characteristics
Model
D2VW-01
D2VW-5
Operating speed
0.1 mm to 1 m/s (at pin plunger)
Operating frequency
Mechanical: 300 operations/minute max.
Electrical: 30 operations/minute max.
Insulation resistance
100 MΩ min. (at 500 VDC)
Contact resistance
50 mΩ max. (100 mΩ max. for molded lead wire models)
Dielectric strength (See note 2)
1,000 VAC, 50/60 Hz for 1 min. between terminals of the same polarity
1,500 VAC, 50/60 Hz for 1 min. between each current-carrying metal parts and ground, and
between each terminal and non-current-carrying metal parts.
Vibration resistance (See note 3)
Malfunction: 10 to 55 Hz, 1.5 mm double amplitude
Shock resistance (See note 3)
Destruction: 1,000 m/s2 (approx. 100G) max.
Malfunction: 300 m/s2 (approx. 30G) max.
Degree of protection
IEC IP67 (excluding the terminals on terminal models).
Degree of protection against electric shock Class I
Proof tracking index (PTI)
175
Ambient operating temperature
-40° to 85°C (at 60% RH max.) with no icing
Ambient operating humidity
95% max. (for 5°C to 35°C)
Life expectancy
Mechanical 10,000,000 operations min. at 60 operations per minute
Electrical
1,000,000 operations min. at 30 ops. per minute. 100,000 operations min. at 30 ops. per minute
Weight
Approx. 7g (pin plunger models without wires)
Note: 1. Data shown are of initial value.
2. The dielectric strength shown is measured using a separator between the switch and metal mounting plate.
3. For the pin plunger models, the above values apply for use at the free position and total travel position. For the lever models, the values
apply at the total travel position.
4. The operating temperature of the lead wire (AV0.75f) for non-UL/CSA molded lead wire models is between -40 to 85°C.
■ Ratings (reference values)
D2VW-5
Rated Voltage
125 VAC
250 VAC
30 VDC
125 VDC
Non-inductive load
Resistive load
Lamp load
NC
NO
NC
NO
5A
0.5 A
5A
0.5 A
5A
3A
0.4 A
0.1 A
Inductive load
Inductive load
Motor load
NC
NO
NC
NO
4A
—
4A
—
4A
—
0.4 A
—
D2VW-01
Rated Voltage
125 VAC
30 VDC
Non-inductive load
Resistive load
Lamp load
NC
NO
NC
NO
0.1 A
—
0.1 A
—
Inductive load
Inductive load
Motor load
NC
NO
NC
NO
—
—
—
—
Note: 1. The resistive load ratings apply under the following test conditions:
Ambient Temperature = 20±2°C, Ambient Humidity = 65±5%, Operating frequency = 30 operations/min.
2. The above current ratings are the values of the steady-state current.
3. Inductive load has a power factor of 0.7 min. (AC) and a time constant of 7 ms max. (DC).
4. Lamp load has an inrush current of 10 times the steady-state current.
5. Rating for UL/CSA approval is as follows (See “Approved Standards” section):
D2VW-01
D2VW-5
0.1A @ 125 VAC
0.1A @ 30 VDC
3A @ 125 VAC, 250 VAC
208
Sealed Snap Action Switch D2VW