English
Language : 

E3C-S10 Datasheet, PDF (16/18 Pages) Omron Electronics LLC – Photoelectric Sensor
E3C
E3C-C ON-Delay Timing Chart
E3C-C One-Shot Timing Chart
E3C
E3C-C OFF-Delay Timing Chart
s E3C-JB4P, E3C-JC4P AMPLIFIERS
Stability
indicator
(green LED)
Sensitivity
adjuster
OFF-delay
selector
switch
Light
incident
(red LED)
Light-ON/
Dark-ON
operation
selector
switch
Timing Charts
Light-ON
Light beam
Incident
Interrupted
LIGHT
indicator
Transistor Output
(1 ms)
Transistor Output
(40 ms OFF-delay)
ON
OFF
ON
OFF
ON
OFF
Dark-ON
Light beam
Incident
Interrupted
LIGHT
ON
indicator
OFF
Transistor Output
ON
(1 ms)
OFF
Transistor Output
(40 ms OFF-delay)
ON
OFF
Alarm Output Timing Chart
The alarm output operates when the control output approaches
critical OFF or ON state for more than 300 ms. An unstable
state occurs when the amount of light incident upon the
receiving element is within 20% of the amount of light needed
to change the control output state.
The alarm output feature is designed to indicate gradual
changes in sensor/reflector position, atmosphere, temperature
or ambient light which result in an unstable control output. A
change occurring less than 300 ms will not cause the alarm
output to operate.
A 300 ms time delay is built into the alarm output circuit. This
prevents false triggering of the alarm output as the leading and
trailing edges of the object to be detected are sensed. The
time can be extended by using an ON-delay timer in the circuit.
Operation level 120%
Operation level
Operation level 80%
Control output
On
(light on mode)
Off
Self-diagnostic
output
On
Off
300 ms max.
17
300 ms max.