English
Language : 

E39R1 Datasheet, PDF (15/24 Pages) Omron Electronics LLC – Photoelectric Sensors E3F2
Model
E3F2-LS10C4-@
Output transistor
status
ON when light is
incident.
(Light-ON)
Timing chart
Incident
Interrupted
Output
indicator
(red)
Output
transistor
ON
OFF
ON
OFF
Load
Operate
(relay) Release
ON when light is
interrupted. (Dark-
ON)
Incident
Interrupted
Output
indicator
(orange)
Output
transistor
ON
OFF
ON
OFF
Load
(relay)
Operate
Release
Note: Terminal numbers for connector type.
■ AC Output
Model
E3F2-3LZ
Output transistor
status
–
–
Timing chart
E3F2-3Z1
E3F2-R2Z1
E3F2-DS10Z1-N
E3F2-3Z2
E3F2-R2Z2
E3F2-DS10Z2-N
ON when light is
incident.
(Light-ON)
ON when light is
interrupted. (Dark-
ON)
Incident
Interrupted
Output
indicator
(red)
Output
transistor
ON
OFF
ON
OFF
Load
Operate
(relay) Release
Incident
Interrupted
Output
indicator
(red)
Output
transistor
ON
OFF
ON
OFF
Load
Operate
(relay) Release
Connection
method
Connect the
pink (Pin 2 )
and brown
(Pin 1 ) cords or
open the pink
cord (Pin 2 ).
Connect the
pink (Pin 2 )
and blue
(Pin 3 ) cords.
Output circuit
Output
indicator
Orange
Stability
indicator*
Green
Main
circuit
Brown
1
10 to 30 VDC
Black
4
100 mA
max.
Load
Blue
3
0V
ZD: VZ = 36 V
Pink
2
Mode selection
Connector Pin Arrangement
1
24
3
Output
indicator
Orange
Stability
indicator*
Green
Main
circuit
Brown
1
10 to 30 VDC
Black
4
100 mA
max.
Load
Blue
3
0V
ZD: VZ = 36 V
Pink
2
Mode selection
Connector Pin Arrangement
1
24
3
Connection
method
–
Output circuit
Through-beam emitter
Power
indicator
(red)
Brown
Main
circuit
24 to 240 VAC
Blue
–
Light
indicator
Red
Brown
200 mA
max.
Black
Load
Main
–
circuit
Blue
24 to 240 VAC
Photoelectric Sensors E3F2
15