English
Language : 

E39R1 Datasheet, PDF (13/24 Pages) Omron Electronics LLC – Photoelectric Sensors E3F2
Model
E3F2-10B4-@
Output transistor
status
–
Timing chart
Test
input
Light
emission
Indicator
ON
OFF
ON
OFF
ON
OFF
Connection
method
–
Output circuit
Through-beam emitter
Red
ON when light is
incident.
(Light-ON)
Incident
Interrupted
Output
indicator
(orange)
Output
transistor
ON
OFF
ON
OFF
Load
(relay)
Operate
Release
ON when light is
interrupted. (Dark-
ON)
Incident
Interrupted
Output
indicator
(orange)
Output
transistor
ON
OFF
ON
OFF
Load
(relay)
Operate
Release
E3F2-LS10B4-@
ON when light is
incident.
(Light-ON)
Incident
Interrupted
Output
indicator
(orange)
Output
transistor
ON
OFF
ON
OFF
Load
(relay)
Operate
Release
ON when light is
interrupted. (Dark-
ON)
Incident
Interrupted
Output
indicator
(orange)
Output
transistor
ON
OFF
ON
OFF
Load
(relay)
Operate
Release
Note: Terminal numbers for connector type.
Connect the
pink (Pin 2 )
and brown
(Pin 1 ) cords or
open the pink
cord (Pin 2 ).
Connect the
pink (Pin 2 )
and blue
(Pin 3 ) cords.
Connect the
pink (Pin 2 )
and brown
(Pin 1 ) cords or
open the pink
cord (Pin 2 ).
Connect the
pink (Pin 2 )
and blue
(Pin 3 ) cords.
Output
indicator
Orange
Brown
1
10 to 30 VDC
Main
circuit
ZD
Black
4
ZD: VZ = 36 V
Blue
3
100 mA
max.
Load
0V
Pink
2
Mode selection
Connector Pin Arrangement
1
24
3
Output
indicator
Orange
Brown
1
10 to 30 VDC
Main
circuit
Black
4
ZD: VZ = 36 V
Blue
3
100 mA
max.
Load
0V
Pink
2
Mode selection
Connector Pin Arrangement
1
24
3
Output
indicator
Orange
Stability
indicator*
Green
Main
circuit
Brown
1
10 to 30 VDC
ZD
Black
4
ZD: VZ = 36 V
Blue
3
100 mA
max.
Load
0V
Pink
2
Mode selection
Connector Pin Arrangement
1
24
3
Output
indicator
Orange
Stability
indicator*
Brown
1
10 to 30 VDC
Green
Main
circuit
Black
4
ZD: VZ = 36 V
Blue
3
100 mA
max.
Load
0V
Pink
2
Mode selection
Connector Pin Arrangement
1
24
3
Photoelectric Sensors E3F2