English
Language : 

K2CM-Q2MA Datasheet, PDF (11/16 Pages) Omron Electronics LLC – Solid-state Relay Enables Choice of Three Operating Functions (Overcurrent, Openphase, and Reverse-phase)
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Surface-mounting Models
126
80
6
60 52 46.5
55
33
11
Six, M3 terminal screws
K2CM
11.5
15
48.5
4
120
36
Three, 20-dia. holes 33.5
33.5
Four, 6-dia. mounting holes or
four, M5 mounting-screw holes
80±0.5
52±0.5
Operating Procedures
■ Operation, Setting, and Indication
Based on the current value of the motor to be used, perform the setting of each item of the K2CM Motor Protective Relay.
List of Current Settings (when using a 200-VAC motor)
Type*
Number of passes
Setting Time scale value
Current setting range (A)
Motor*** Rated output (kW) Rated current (A)**
0.2
1.8
0.4
2.8
0.75
4.2
1.5
7.3
2.2
10
3.7
16.1
5.5
24
7.5
32
11
45
15
61
18.5
74
22
87
30
117
37
143.0
K2CM-@@LS@
1
2 to 8
2 to 8
K2CM-@@L@
1
2
4
8
8 to 26
8 to 26 4 to 13 2 to 6.5 1 to 3.25
K2CM-@@M@
1
20 to 65
20 to 65
K2CM-@@H@
1
50 to 160
50 to 160
* The squares (@) represent the symbols defined under Model Number Legend.
** The rated current is the current at full load.
*** Supply: Low-voltage 3-phase basket type inductive motor, full-load characteristics of 200 VAC, 4-pole, totally-enclosed.
Note: When using a large-capacity or high-voltage motor whose capacity is 45 kW or more, calculate the rated current/alternating current ratio by
converting with the alternating current ratio of the external current transformer.
11