English
Language : 

E3JM-R4M4-US Datasheet, PDF (11/13 Pages) Omron Electronics LLC – Built-in Power Supply Photoelectric Sensor
E3JM/E3JK
● Wiring
Connecting and Wiring
• We recommend connecting a cable with a conductor cross-section
of 0.3 mm2 and an outer diameter of 6 to 8 mm.
• Be sure to firmly tighten the cover in order to maintain waterproof
and dustproof properties. The screw size of the conduit sockets is
shown in the following table.
Model
E3JM-@
Conduit socket thread size
PF1/2
Cable End Treatment
Adjust the four wires to the same length when
the Ta output is to be used only. If both the Ta
and Tb outputs are to be used, treat them as
shown in the following diagram.
Recommended example
Approx.
45 mm
Power
source
Tc, Ta
Tb
Approx.
55 mm
Rubber bushing (provided)*
Washer (provided)*
Tightening nut (provided)*
* These parts are not provided with models with a -US suffix.
Recommended Crimp Terminal Dimensions (Unit: mm)
Round type
Fork type
10 max.
10 max.
7 max.
3.6 dia. min.
19 max.
7 max. 7 max.
3.6 dia. min.
19 max.
7 max.
(After crimping)
(After crimping)
Note: Use terminals with insulation tube (recommended crimp terminal: 1.25 to
3.5).
● Others
Terminal Protection Cover (Provided)
The terminal protection cover is designed to improve safety by
maintaining the sensitivity properties of the product and by preventing
any contact with charged sections while it is being operated with the
mode set to the timer mode. Mount the product as shown in the
following diagram (mount the Through-beam Model on the Receiver
side).
E3JK
● Designing
Power Reset Time
The Sensor is ready to detect within 200 ms after it is turned ON. If
the Sensor and load are connected to separate power supplies, be
sure to turn ON the Sensor first.
Items Common to
E3JM and E3JK
● Wiring
Connecting and Wiring DC SSR Output Models
When using the DC SSR output model, the total of the load current for
the Light-ON output (NO) and that for the Dark-ON (NC) should be
100 mA max. If the total exceeds 100 mA, the load short-circuit
protection function will be activated (this function will be reset when
the power of the Photoelectric Sensor is turned OFF).
● Others
Ambient Conditions (Installation Area)
The E3JM will malfunction if installed in the following places.
• Places where the E3JM is exposed to a dusty environment.
• Places where corrosive gases are produced.
• Places where the E3JM is directly exposed to water, oil, or
chemicals.
Terminal protection cover
E3JM
11